Specific Process Knowledge/Etch/DRIE-Pegasus/nanoetch/nano11

From LabAdviser

The nano1.1 recipe

Recipe nano1.1
Recipe Gas C4F8 38 sccm, SF6 52 sccm
Pressure 4 mTorr, Strike 3 secs @ 15 mTorr
Power 600 W CP, 50 W PP
Temperature 10 degs
Hardware 100 mm Spacers
Time 120 secs
Conditions Run ID 1815
Conditioning Sequence: Oxygen clean, MU tests, processes, no oxygen between runs
Mask 1dfhj10 nm zep etched down to 6dgh4 nm



Comments

The lower coil power run may still be isotropic-looking either because of a lack of deposition in the process, or because the bias increases as the coil power is decreased, hence the wafer would have received a more phyisically-aggressive process. Lower temp, lower coil + lower platen may be worth a look.