Specific Process Knowledge/Pattern Design: Difference between revisions
Line 35: | Line 35: | ||
* [[Media:Beginners_guide_to_mask_design_using_Clewin_v1.4.pdf|"Beginners guide to mask design" here]] and | * [[Media:Beginners_guide_to_mask_design_using_Clewin_v1.4.pdf|"Beginners guide to mask design" here]] and | ||
* [[Media:Guide to mask making.pdf | Guide to mask making.pdf]]. Unfortunately this is quite old, but may be useful anyway. Note some links/e-mails etc. are not correct anymore and the mask specifications (CU/CD, DF/BF, RR/WR) are no longer valid. | * [[Media:Guide to mask making.pdf | Guide to mask making.pdf]]. Unfortunately this is quite old, but may be useful anyway. Note some links/e-mails etc. are not correct anymore and the mask specifications (CU/CD, DF/BF, RR/WR) are no longer valid. | ||
* [[Media: | * [[Media:Mask_polarity_and_orientation.pdf | Mask polarity and orientation.pdf]]. This is an updated guide how to specify the polarity and orientation of the mask when ordering as well as when used on our maskless aligners.Be aware that the specification of polarity and orientation when ordering at Compugraphics is not the same as when ordering at Delta Mask as we used to do. | ||
===Alignment marks=== | ===Alignment marks=== |
Revision as of 10:00, 22 August 2019
Feedback to this page: click here
Pattern Design and Mask Fabrication
Feedback to this page: click here
Pattern Design
For making a pattern on a substrate it is necessary to use a software tool to design the pattern layout. This counts for all kind of lithography and laser cutting. There are a number of differernt software tools that can be used, some of the more commonly used are:
- CleWin
- L-Edit
- Autocad
At Danchip we offer all users free access to CleWin 5 for their mask layout.
Install CleWin 5 software on your local computer: Click here for guidelines.
Layout file format
- For E-beam lithography you need to prepare a set of files (GDS, V30, sdf, jdf and mgn files). For details about how to prepare the files for E-beam lithography, please see File preparation. For details about how to make alligned E-beam patterns, please have at look at Design of global marks and chip marks
- For laser cutting the layout file has to be saved as a DXF file that is uploaded to the equipment computer.
- For UV-lithography it is necessary to have a physical mask produced based on a layout file. The file format has to be CIF or GDS. For more details see below Mask Fabrication for UV-lithography.
- For DUV-lithography and DUV-lithography it is necessary to have physical masks (reticles) produced based on the layout file. The file format has to be GDS. For more details concerning the design of reticles see Design of Reticles.
Mask Fabrication for UV-lithography
Tips and tricks for mask designing
You can find a
- "Beginners guide to mask design" here and
- Guide to mask making.pdf. Unfortunately this is quite old, but may be useful anyway. Note some links/e-mails etc. are not correct anymore and the mask specifications (CU/CD, DF/BF, RR/WR) are no longer valid.
- Mask polarity and orientation.pdf. This is an updated guide how to specify the polarity and orientation of the mask when ordering as well as when used on our maskless aligners.Be aware that the specification of polarity and orientation when ordering at Compugraphics is not the same as when ordering at Delta Mask as we used to do.
Alignment marks
The following alignment marks are suggested to use on the EVG620 automatic aligner for good pattern recognition. Pleased be adviced that they can be removed in KOH etching.
- Alignment marks 2 .cif - You need the program "Clewin" to open this file
- Alignment marks 2 .tdb - You need the program "L-Edit" to open this file
Alignment marks location
For the KS Aligner, MA6-2 and Aligner-6inch
- The mask's alignment marks for 4inch process:
- For Back Side Alignment (BSA) alignment marks must be located between -1,0 and +1,0 mm in vertical location from mask center (y=0-+1mm) and exactly at 45mm in left and right in horizontal location (x=+-45mm).
- For Top Side Alignment (TSA) alignment marks must be located 35-45 mm in left and right in horizontal location and between -2 and +2 mm in vertical location.
- The mask's alignment marks for 6inch process:
- Both BSA and TSA must be located between -2,5 and +2,5 mm in vertical location from mask center and 60 mm in left and right in horizontal location.
- Please notice that if you plan to use the automatic alignment option the alignment marks must be displaced from y=0 to y=+/- 1,6mm.
Alignment marks for E-beam lithography
If your UV mask is used to define wafers marks in e-beam lithography with JEOL JBX-9500, you should design your alignment marks in a way the JEOL JBX-9500 recognizes. Please follow the guide here.
Mask Ordering and Fabrication
How to order a mask
Our standard mask supplier is Compugraphics. They can provide 5" and 7" masks on soda lime glass or quartz. Minimum feature size can be 0.8µm, 1µm or 1.5µm which is reflected in the price. Read a short guide on how to order photomasks from Compugraphics here. Templates for the mask specifications for 5" and 7" masks respectively can be seen here.
The masks have to be ordered in Procure. Nanolab cannot order the mask for you but we do offer a final check of the design and mask specifications before you place the order. You can find a guide on how to order and attach design files in procure here.
If you are using L-edit to design your mask you should remember to mark the top cell as the fabrication cell; a small pink f should show to the left of the cell name in the Design Navigator.
Remember to make only the layers for fabrication visible. The remaining should be invisible. Give each layer appropriate GDS number respectively CIF names before exporting the file. This is done by double click on the layers and fill out the window that pops up.
We can also provide guidance regarding the mask design phase. Please contact the mask team for help and review, E-mail address can be found in Nanolab contact information.
Mask sets made by Danchip
Danchip quality control masks
This section contains a description of some of the quality control designs.
ASE standardisation designs: The quality control procedure on the ASE is using the daqmask 2 mask
RIE standardisation design:
The quality control procedures on RIE2 is using the dASEfeRIE mask
Masks for process development