Line 102: Line 102:




==QC template  - try to make you QC recipe + limits look as much as possible like this==
{| border="1" cellspacing="2" cellpadding="2" colspan="3"
|bgcolor="#98FB98" |'''Quality Controle (QC) for RIE1 and RIE2'''
|-
|
*[http://labmanager.danchip.dtu.dk/d4Show.php?id=1389&mach=18 The QC procedure for RIE1 and RIE2]<br>
*[http://www.labmanager.danchip.dtu.dk/view_binary.php?type=data&mach=18 The newest QC data for RIE1]<br>
*[http://www.labmanager.danchip.dtu.dk/view_binary.php?type=data&mach=19 The newest QC data for RIE2]
{| {{table}}
| align="center" |
{| border="1" cellspacing="1" cellpadding="2"  align="center" style="width:200px"
! QC Recipe:
! OH_POLYA
|-
| SF<sub>6</sub> flow
|32 sccm
|-
|O<sub>2</sub> flow
|8 sccm
|-
|Pressure
|80 mTorr
|-
|RF-power
|30 W
|-
|Etch Load
|50%
|-
|}
| align="center" valign="top"|
{| border="2" cellspacing="1" cellpadding="2" align="center" style="width:500px"
!QC limits
!RIE1
!RIE2
|-
|Etch rate in Si
|0.2 - 0.6 µm/min
|0.2 - 0.6 µm/min
|-
|Non-uniformity
|2 - 5 %
|2 - 5 %
|-
|}
|-
|}
|}