Jump to content

LabAdviser/314/Preparation 314-307: Difference between revisions

Mktracy (talk | contribs)
Mktracy (talk | contribs)
Line 226: Line 226:
'''RMC MT-7 Microtome'''
'''RMC MT-7 Microtome'''


Our RMC MT-7 Microtome is a vintage piece of equipment and can be used for planning specimens for SEM/EDX and/or for cutting relative thin slices (approx. 200nm thick) for TEM. First, the specimen needs to be embedded into a resin or an epoxy, and then can be sliced with a glass or diamond knife.  At DTU Nanolab Cen we can offer only glass knifes. The Risk Assessment for the RMC MT-7 Microtome can be found here [[:File:APV RMC Microtome.pdf]]
Our RMC MT-7 Microtome is a vintage piece of equipment and can be used for planning specimens for SEM/EDX and/or for cutting relative thin slices (approx. 200nm thick) for TEM. First, the specimen needs to be embedded into a resin or an epoxy, and then can be sliced with a glass or diamond knife.  At DTU Nanolab Cen we can offer only glass knifes.  
The RMC MT-7 Microtome is located in building 314, in the Soft Mater preparation lab.
 
 
Risk Assessment: [[:File:APV RMC Microtome.pdf]]
 


For further information about the machine usage contact afull@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=65646&cpid=173468&tab=2&qt=dtupublicationquery].
For further information about the machine usage contact afull@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=65646&cpid=173468&tab=2&qt=dtupublicationquery].


[[File: RMC Microtome.jpg|200px|thumb|left|DTU Nanolab RMC MT-7 Microtome]]
[[File: RMC Microtome.jpg|200px|thumb|left|RMC MT-7 Microtome Location at DTU Nanolab Building 314]]


<br clear="all" />
<br clear="all" />
Line 248: Line 251:
For further information about the machine usage contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0].
For further information about the machine usage contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0].


[[File:Leica EM UC7.jpg|400px|left|thumb|Location at DTU Nanolab Building 307, Room 906]]<br />
[[File:Leica EM UC7.jpg|400px|left|thumb|Leica EM UC7 Location at DTU Nanolab Building 307, Room 906]]<br />


<br clear="all" />
<br clear="all" />
Line 264: Line 267:
For further information about the machine usage contact merafik@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=135492&cpid=245590&tab=0] or mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0].  
For further information about the machine usage contact merafik@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=135492&cpid=245590&tab=0] or mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0].  


[[File:Leica EM FC7.jpg|400px|left|thumb|Location at DTU Nanolab Building 307, Room 906]]<br />
[[File:Leica EM FC7.jpg|400px|left|thumb|Leica EM FC7 Location at DTU Nanolab Building 307, Room 906]]<br />


<br clear="all" />
<br clear="all" />