Compared to exposure on KS-Aligner, the dose on Aligner-6inch is halved.
Compared to exposure on KS-Aligner, the dose on Aligner-6inch is halved.
*1.5µm: 24.5 mJ/cm<sup>2</sup> corresponding to 3.5 seconds exposure at 7 mW/cm<sup>2</sup>.
*1.5µm: 24.5 mJ/cm<sup>2</sup> corresponding to 3.5 seconds exposure at 7 mW/cm<sup>2</sup>.
*10µm: ~140 mJ/cm<sup>2</sup> corresponding to ~20 seconds exposure at 7 mW/cm<sup>2</sup>.
*10µm: ~140 mJ/cm<sup>2</sup> corresponding to ~20 seconds exposure at 7 mW/cm<sup>2</sup>. Multiple exposure with 10s pauses is recommended.


'''AZ MiR 701''' ''Preliminary results''
'''AZ MiR 701''' ''Preliminary results''