Specific Process Knowledge/Characterization/Optical microscope: Difference between revisions

From LabAdviser
Kabi (talk | contribs)
No edit summary
Kabi (talk | contribs)
No edit summary
 
(One intermediate revision by the same user not shown)
Line 13: Line 13:
!Noco IR
!Noco IR
!Leica INM 100
!Leica INM 100
!Nikon Eclipse L200 #2
!Zeiss Jenatech
!Zeiss Jenatech
!Nikon Eclipse L200 #1
!Nikon Eclipse L200 #1
!Leitz Medilux
!Nikon Eclipse L200 #2
!Nikon Eclipse L200N #3
!Nikon Eclipse L200N #3
!Nikon Eclipse L200N #4
!Nikon Eclipse L200N #4
Line 30: Line 29:
|[[image:Noco IR microscope.jpg|100x100px|thumb|center]][[image:Noco IR microscope_1.jpg|100x100px|thumb|center]]
|[[image:Noco IR microscope.jpg|100x100px|thumb|center]][[image:Noco IR microscope_1.jpg|100x100px|thumb|center]]
|[[image:LeicaINM100.jpg|100x100px|thumb|center]]
|[[image:LeicaINM100.jpg|100x100px|thumb|center]]
|[[image:Nikon Eclipse L200 2.jpg|100x100px|thumb|center]][[image:Nikon Eclipse L200 2_1.jpg|100x100px|thumb|center]]
|[[image:Zeiss Jenatech strain.jpg|100x100px|thumb|center]][[image:Zeiss Jenatech strain_1.jpg|100x100px|thumb|center]]
|[[image:Zeiss Jenatech strain.jpg|100x100px|thumb|center]][[image:Zeiss Jenatech strain_1.jpg|100x100px|thumb|center]]
|[[image:Nikon Eclipse L200.jpg|100x100px|thumb|center]][[image:Nikon Eclipse L200_1.jpg|100x100px|thumb|center]]
|[[image:Nikon Eclipse L200.jpg|100x100px|thumb|center]][[image:Nikon Eclipse L200_1.jpg|100x100px|thumb|center]]
|[[image:Leitz Medilux.jpg|100x100px|thumb|center]]
|[[image:Nikon Eclipse L200 2.jpg|100x100px|thumb|center]][[image:Nikon Eclipse L200 2_1.jpg|100x100px|thumb|center]]
|[[image:Nikon Eclipse L 200 3_1.jpg|100x100px|thumb|center]]
|[[image:Nikon Eclipse L 200 3_1.jpg|100x100px|thumb|center]]
|[[image:Nikon Eclipse L 200 4_1.jpg|100x100px|thumb|center]]
|[[image:Nikon Eclipse L 200 4_1.jpg|100x100px|thumb|center]]
Line 47: Line 45:
|346-901
|346-901
|346-901
|346-901
|cleanroom F3
|cleanroom A1
|cleanroom A1
|cleanroom D3
|cleanroom D3
|no longer in use
|cleanroom F3
|cleanroom E4
|cleanroom E4
|cleanroom E5
|cleanroom E5
Line 64: Line 61:
|Wet chemistry
|Wet chemistry
|Wet chemistry
|Wet chemistry
|Lithography
|Lithography
|Lithography
|Lithography
|Lithography
Line 91: Line 87:
*50x
*50x
|
|
*2.5x
*5x
*5x
*10x
*10x
Line 98: Line 93:
*100x
*100x
|
|
*2.5x
*5x
*5x
*10x
*10x
*20x
*20x
*50x
*50x
*100x
|
|
*2.5x
*2.5x
Line 110: Line 105:
*50x
*50x
*100x
*100x
|
*2.5x
*5x
*10x
*20x
*50x
|
|
*2.5x
*2.5x
Line 147: Line 136:
|-style="background:WhiteSmoke; color:black; vertical-align:middle; text-align:left;"
|-style="background:WhiteSmoke; color:black; vertical-align:middle; text-align:left;"
!Ocular
!Ocular
|10x
|10x
|10x
|10x
|10x
Line 166: Line 154:
|Stereoscopic microscope
|Stereoscopic microscope
|IR imaging
|IR imaging
|
|
|
|
|
Line 188: Line 175:
*Polarizer
*Polarizer
*Brightfield
*Brightfield
|
*Brightfield
*Darkfield
|
|
*Brightfield
*Brightfield
Line 202: Line 186:
|
|
*Brightfield
*Brightfield
*Darkfield
|
|
*Polarizer
*Polarizer
Line 226: Line 211:
|
|
*Episcopic
*Episcopic
|
*Episcopic
*Diascopic
|
|
*Episcopic
*Episcopic
Line 265: Line 247:
|IR camera
|IR camera
|DS-Fi2
|DS-Fi2
|None
|DS-Fi1
|DS-Fi1
|None
|DS-Fi1
|DS-Fi1
|DX40-274FW
|
|
*DS-Fi2
*DS-Fi2
Line 285: Line 266:
|None
|None
|None
|None
|NIS-D
|NIS-D
|NIS-D
|None
|None
|NIS-BR
|NIS-BR
|Kappa Control Center
|NIS-D
|NIS-D
|NIS-D
|NIS-D
|NIS-D

Latest revision as of 11:35, 7 November 2023

Feedback to this page: click here

This page is written by DTU Nanolab internal

Nikon SMZ 1000 Noco IR Leica INM 100 Zeiss Jenatech Nikon Eclipse L200 #1 Nikon Eclipse L200 #2 Nikon Eclipse L200N #3 Nikon Eclipse L200N #4 Nikon ME 600 Leica S8 APO Zeiss Axiotron
Location 346-901 346-901 346-901 cleanroom A1 cleanroom D3 cleanroom F3 cleanroom E4 cleanroom E5 cleanroom F1 cleanroom Cx1 cleanroom D3
Responsible group Wet chemistry Wet chemistry Wet chemistry Lithography Lithography Lithography Lithography Lithography Lithography Lithography Lithography
Objectives Zoom 0.8x - 8x
  • 2.5x
  • 10x
  • 20x
  • 50x
  • 2.5x
  • 5x
  • 10x
  • 20x
  • 50x
  • 5x
  • 10x
  • 20x
  • 50x
  • 100x
  • 2.5x
  • 5x
  • 10x
  • 20x
  • 50x
  • 2.5x
  • 5x
  • 10x
  • 20x
  • 50x
  • 100x
  • 2.5x
  • 5x
  • 10x
  • 20x
  • 50x
  • 100x
  • 2.5x
  • 5x
  • 10x
  • 20x
  • 50x
  • 100x
  • 5x
  • 10x
  • 20x
  • 50x
  • 100x
Zoom 1x - 8x
  • 5x
  • 10x
  • 20x
  • 50x
Ocular 10x 10x 10x 10x 10x 10x 10x 10x 10x 10x 10x
Special features Stereoscopic microscope IR imaging Stereoscopic microscope
Contrast mechanisms
  • Brightfield
  • Polarizer
  • Brightfield
  • Brightfield
  • Darkfield
  • Polarizer
  • Brightfield
  • Brightfield
  • Darkfield
  • Brightfield
  • Darkfield
  • Polarizer
  • Brightfield
  • Darkfield
  • Polarizer
  • Brightfield
  • Darkfield
  • Polarizer
  • Brightfield
  • Darkfield
  • Brightfield
  • Brightfield
  • Darkfield
Illumination modes
  • Episcopic
  • Episcopic
  • Diascopic
  • Episcopic
  • Diascopic
  • Episcopic
  • Diascopic
  • Episcopic
  • Diascopic
  • Episcopic
  • Diascopic
  • Episcopic
  • Diascopic
  • Episcopic
  • Diascopic
  • Episcopic
  • Episcopic
  • Episcopic
  • Diascopic
Camera None IR camera DS-Fi2 None DS-Fi1 DS-Fi1
  • DS-Fi2
  • C-mount, 0.7x relay
  • DS-Fi2
  • C-mount, 0.7x relay
DS-Fi2 None Infinity X
Analysis software None None NIS-D None NIS-BR NIS-D NIS-D NIS-D NIS-D None DeltaPix


There are also two optical microscopes in building 451, a stereo microscope and a transmission microscope, that were both previously located in Packlab. Please ask staff / the BioMic group for details.