'''Feedback to this page''': '''[mailto:labadviser@nanolab.dtu.dk?Subject=Feed%20back%20from%20page%20http://labadviser.nanolab.dtu.dk/index.php/LabAdviser/314/Microscopy_314-307/TEM/Sample_Holders click here]''' | '''Feedback to this page''': '''[mailto:labadviser@nanolab.dtu.dk?Subject=Feed%20back%20from%20page%20http://labadviser.nanolab.dtu.dk/index.php/LabAdviser/314/Microscopy_314-307/TEM/Sample_Holders click here]''' | ||
''This section is written by DTU Nanolab internal if nothing else is stated.'' | |||
[[Category:314]] | [[Category:314]] | ||
[[Category:314-Microscopy]] | [[Category:314-Microscopy]] | ||
Line 39: | Line 40: | ||
= Holders for heating experiments = | = Holders for heating experiments = | ||
== | == DENSsolution Wildfire single tilt heating holder == | ||
MEMS-based holder for heating up to 1300°C. It is a single tilt holder which is also suitable for EDS. | MEMS-based holder for heating up to 1300°C. It is a single tilt holder which is also suitable for EDS. | ||
Line 80: | Line 81: | ||
= Special Holders = | = Special Holders = | ||
== | == DENSsolution Climate gas and heating holder == | ||
The MEMS-based closed-cell holder offers the possibility of gas environments up to atmospheric pressure (1bar). Up to three gasses can be used simultaneously. Additionally, it offers temperature control up to 1000°C. The setup is also equipped with an residual gas analyzer to detect reaction products. | |||
<br> | |||
== Fischione two-contact biasing holder == | == Fischione two-contact biasing holder == | ||
<br> | <br> |
Latest revision as of 09:20, 27 June 2023
Feedback to this page: click here
This section is written by DTU Nanolab internal if nothing else is stated.
THIS PAGE IS UNDER CONSTRUCTION
Holders for general imaging
Fischione 2020 tomography holder
FEI single tilt holder
Standard sample holder available for the Tecnai microscopes and the ATEM.
FEI double tilt
The holder has a beta-tilt of about +/-30°. The specimen cradle and clamping material (hexring and anti-twist washer) are made of beryllium to minimize unwanted X-ray signal from the holder.
Gatan double tilt beryllium holder
The holder has a beta-tilt of about +/-30°. The specimen cradle and clamping material (hexring and anti-twist washer) are made of beryllium to minimize unwanted X-ray signal from the holder. The holder has a Faraday-cup at the tip for possible measurement of the beam current (with an external picoampermeter).
Holders for EDS analyses
Gatan double tilt beryllium holder
The holder has a beta-tilt of about +/-30°. The specimen cradle and clamping material (hexring and anti-twist washer) are made of beryllium to minimize unwanted X-ray signal from the holder. The holder has a Faraday-cup at the tip for possible measurement of the beam current (with an external picoampermeter).
FEI double tilt
The holder has a beta-tilt of about +/-30°. The specimen cradle and clamping material (hexring and anti-twist washer) are made of beryllium to minimize unwanted X-ray signal from the holder.
Holders for heating experiments
DENSsolution Wildfire single tilt heating holder
MEMS-based holder for heating up to 1300°C. It is a single tilt holder which is also suitable for EDS.
Protochips Fusion Select double tilt heating holder
This MEMS-based holder has 6 contacts, which allows for heating, electrical biasing/measuring and the combination of both. It has beta-tilt capabilities up to about +/- 20° and is suitable for EDS. The chips can be heated up to about 1200°C.
Gatan 652 In double tilt heating holder
Classical furnace heating holder which is suited for standard 3mm samples. The heating furnace is made from Inconel and suited for heating in oxidizing gas environments (ETEM) up to about 800°C. This holder is not suited for EDS because of the furnace design.
Gatan 652 Ta double tilt heating holder
Classical furnace heating holder which is suited for standard 3mm samples. The heating furnace is made from tantalum and ONLY suited for heating in non-oxidizing gas environments (ETEM) up to about 1000°C. This holder is not suited for EDS because of the furnace design.
Holders for cryo experiments
Gatan single tilt cryo holder
Gatan double tilt liquid nitrogen cold holder
He cooling holder
Holders for tomography
Fischione 2020 tomography holder
Fischione 2040 dual axis tomography holder
Fischione 2070 vacuum transfer tomography holder
Special Holders
DENSsolution Climate gas and heating holder
The MEMS-based closed-cell holder offers the possibility of gas environments up to atmospheric pressure (1bar). Up to three gasses can be used simultaneously. Additionally, it offers temperature control up to 1000°C. The setup is also equipped with an residual gas analyzer to detect reaction products.
Fischione two-contact biasing holder