=Aligner: MA6-1= | |||
[[ | [[File:KSAligner in E-4.jpg|400px|thumb|The Aligner: MA6-1 is located in PolyFabLab.]] | ||
'''Tool description'''<br> | |||
The Aligner: MA6-1 is a manual UV exposure system, which can be used for mask alignment and exposure of UV resists on 100 mm substrates. It is also capable of flood exposing chips, 50 mm and 150 mm substrates. | |||
{| class="wikitable" | |||
! style="text-align:left" | Product: | |||
| style="padding-left: 10px" | Süss mask aligner MA6 | |||
|- | |||
! style="text-align:left" | Year of purchase: | |||
| style="padding-left: 10px" | 1999 | |||
|- | |||
! style="text-align:left" | Location: | |||
| style="padding-left: 10px" | PolyFabLab | |||
|} | |||
'''User manual'''<br> | |||
The user manual and contact information can be found in [http://labmanager.dtu.dk/function.php?module=Machine&view=view&mach=44 LabManager] - '''requires login''' | |||
'''Tool training'''<br> | |||
Training on the tool requires users to complete the [https://labadviser.nanolab.dtu.dk//index.php?title=Specific_Process_Knowledge/Lithography#Lithography_Tool_Package_Training lithography TPT] followed by reading the manual and watching the training videos. The tool authorization can be obtained after a successful hands-on authorization training session.<br> | |||
The training videos were made for MA6-2, but operation of MA6-1 is very similar as they are exactly the same model. Due to a different power supply, however, procedures for ignition and intensity control of the lamp is different for MA6-1. Please refer to the manual for the correct procedures. | |||
[https://www.youtube.com/watch?v=o8IBtfQHNzU Operation] | [https://www.youtube.com/watch?v=o8IBtfQHNzU Operation] | ||
[https://www.youtube.com/watch?v=rvUuXYgw-xU Alignment] | [https://www.youtube.com/watch?v=rvUuXYgw-xU Alignment] | ||
<br clear="all" /> | |||
=Equipment performance and process related parameters= | |||
= | {| class="wikitable" | ||
|- | |||
! scope=row style="text-align: left;" | Purpose | |||
== | | Mask alignment and UV exposure | ||
|- | |||
! scope=row style="text-align: left;" | Exposure modes | |||
| | |||
*Vacuum contact | |||
*Hard contact | |||
= | *Soft contact | ||
*Proximity | |||
| | *Flood exposure | ||
|- | |- | ||
! scope=row style="text-align: left;" | Exposure light/filters | |||
| | |||
*365 nm (i-line) | |||
*broadband (i-, g-, h-lines), requires tool change | |||
*303 nm, requires tool change | |||
|- | |- | ||
! scope=row style="text-align: left;" | Minimum resolution | |||
| ~1.25 µm | |||
|- | |- | ||
| | ! scope=row style="text-align: left;" | Mask size | ||
| | | 5x5 inches | ||
|- | |- | ||
| | ! scope=row style="text-align: left;" | Alignment modes | ||
| | | | ||
*Top side (TSA): ±2 µm | |||
*Back side (BSA): ±5 µm | |||
|- | |- | ||
| | ! scope=row style="text-align: left;" | Substrate size | ||
| | | | ||
*Mask exposure and alignment: 100 mm wafers | |||
*Flood exposure: from samples to 150 mm wafers | |||
|- | |- | ||
| | ! scope=row style="text-align: left;" | Allowed materials | ||
| All PolyFabLab allowed materials | |||
|- | |- | ||
! scope=row style="text-align: left;" | Substrate batch | |||
| 1 | |||
|} | |} | ||
= | <br clear="all" /> | ||
=Process information= | |||
The Aligner: MA6-1 has an i-line notch filter installed. This results in an exposure light peak around 365nm with a FWHM of 7nm. | |||
==Exposure dose== | |||
[[Specific Process Knowledge/Lithography/Resist/UVresist/exposureDoseMaskAligners#Aligner:_MA6-1|Information on UV exposure dose]] | |||
==Alignment mark design and locations== | |||
[[Specific_Process_Knowledge/Pattern_Design#Alignment_marks|Alignment mark design and locations]]. | |||
Latest revision as of 13:46, 26 June 2026
Aligner: MA6-1

Tool description
The Aligner: MA6-1 is a manual UV exposure system, which can be used for mask alignment and exposure of UV resists on 100 mm substrates. It is also capable of flood exposing chips, 50 mm and 150 mm substrates.
| Product: | Süss mask aligner MA6 |
|---|---|
| Year of purchase: | 1999 |
| Location: | PolyFabLab |
User manual
The user manual and contact information can be found in LabManager - requires login
Tool training
Training on the tool requires users to complete the lithography TPT followed by reading the manual and watching the training videos. The tool authorization can be obtained after a successful hands-on authorization training session.
The training videos were made for MA6-2, but operation of MA6-1 is very similar as they are exactly the same model. Due to a different power supply, however, procedures for ignition and intensity control of the lamp is different for MA6-1. Please refer to the manual for the correct procedures.
| Purpose | Mask alignment and UV exposure |
|---|---|
| Exposure modes |
|
| Exposure light/filters |
|
| Minimum resolution | ~1.25 µm |
| Mask size | 5x5 inches |
| Alignment modes |
|
| Substrate size |
|
| Allowed materials | All PolyFabLab allowed materials |
| Substrate batch | 1 |
Process information
The Aligner: MA6-1 has an i-line notch filter installed. This results in an exposure light peak around 365nm with a FWHM of 7nm.
Exposure dose
Information on UV exposure dose