Jump to content

Specific Process Knowledge/Characterization/Optical microscope: Difference between revisions

From LabAdviser
No edit summary
Taran (talk | contribs)
No edit summary
 
(53 intermediate revisions by 11 users not shown)
Line 1: Line 1:
{| border="1" cellspacing="0" cellpadding="6"  
{{cc-nanolab}}
!
 
! Zeiss Jenatech (strain)
'''Feedback to this page''': '''[mailto:labadviser@nanolab.dtu.dk?Subject=Feed%20back%20from%20page%20http://labadviser.nanolab.dtu.dk/index.php/Specific_Process_Knowledge/Characterization/Optical_microscope click here]'''
! Nikon SMZ 1500
 
! Leica S8 APO
[[Category: Equipment|Characterization Optical mi]]
! Zeiss Original
[[Category: Characterization|Optical mi]]
! Leitz Medilux
 
! Zeiss Axiotron 2
{|border="1" cellspacing="1" cellpadding="3" style="text-align:left;"  
! Zeiss Jenatech (particles measurements)
|-
! Noco IR microscope
|-style="background:white; color:black; vertical-align:middle; text-align:center;"
! Nikon SMZ 1000
|
! Nikon ME 600
!Nikon SMZ 1000
! Nikon Eclipse L200
!Noco IR
! Nokin Eclipse L200 (2)
!Leica INM 100
|-  
!Zeiss Jenatech
|Location
!Nikon Eclipse L200 #1
|Cleanroom 15
!Nikon Eclipse L200 #2
|Cleanroom 13
!Nikon Eclipse L200N #3
|Cleanroom 4
!Nikon Eclipse L200N #4
|Cleanroom 4
!Nikon ME 600
|Cleanroom 4
!Leica S8 APO
|Cleanroom Hymite
!Zeiss Axiotron
|Cleanroom 2
|-
|Cleanroom III-V
 
|Cleanroom III-V
|-
|Cleanroom 4
|-style="background:white; color:black; vertical-align:middle; text-align:center;"
|Cleanroom 13
|
|Cleanroom 3
|[[image:Nikon SMZ 1000.jpg|100x100px|thumb|center]]
|-  
|[[image:Noco IR microscope.jpg|100x100px|thumb|center]][[image:Noco IR microscope_1.jpg|100x100px|thumb|center]]
|Special features
|[[image:LeicaINM100.jpg|100x100px|thumb|center]]
|Nomarski prism
|[[image:Zeiss Jenatech strain.jpg|100x100px|thumb|center]][[image:Zeiss Jenatech strain_1.jpg|100x100px|thumb|center]]
|Stereoscopic microscope
|[[image:Nikon Eclipse L200.jpg|100x100px|thumb|center]][[image:Nikon Eclipse L200_1.jpg|100x100px|thumb|center]]
|Stereoscopic microscope
|[[image:Nikon Eclipse L200 2.jpg|100x100px|thumb|center]][[image:Nikon Eclipse L200 2_1.jpg|100x100px|thumb|center]]
|No
|[[image:Nikon Eclipse L 200 3_1.jpg|100x100px|thumb|center]]
|No
|[[image:Nikon Eclipse L 200 4_1.jpg|100x100px|thumb|center]]
|No
|[[image:Nikon ME 600.jpg|100x100px|thumb|center]][[image:Nikon ME 600_1.jpg|100x100px|thumb|center]]
|No
|[[image:Leica S8 APO.jpg|100x100px|thumb|center]]
|IR to visible
|[[image:Zeiss Axiotron.jpg|100x100px|thumb|center]][[image:Zeiss Axiotron_1.jpg|100x100px|thumb|center]]
|Stereoscopic microscope
|-
|No
 
|Motorized stage
|-
|No
|-style="background:LightGrey; color:black; vertical-align:middle; text-align:left;"
!Location
|346-901
|346-901
|346-901
|cleanroom<br>D-3?
|cleanroom<br>D-3
|cleanroom<br>A-1
|cleanroom<br>D-3
|cleanroom<br>E-5
|cleanroom<br>F-1?
|cleanroom<br>Cx1
|cleanroom<br>F-3
|-
 
|-
|-style="background:WhiteSmoke; color:black; vertical-align:middle; text-align:left;"
!Responsible group
|Wet chemistry
|Wet chemistry
|Wet chemistry
|Lithography
|Lithography
|Lithography
|Lithography
|Lithography
|Lithography
|Lithography
|Lithography
|-
 
|-
|-style="background:LightGrey; color:black; vertical-align:middle; text-align:left;"
!Objectives
|Zoom 0.8x - 8x
|
*2.5x
*10x
*20x
*50x
|
*2.5x
*5x
*10x
*20x
*50x
|
*5x
*10x
*20x
*50x
*100x
|
*2.5x
*5x
*10x
*20x
*50x
|
*2.5x
*5x
*10x
*20x
*50x
*100x
|
*2.5x
*5x
*10x
*20x
*50x
*100x
|
*2.5x
*5x
*10x
*20x
*50x
*100x
|
*5x
*10x
*20x
*50x
*100x
|Zoom 1x - 8x
|
*5x
*10x
*20x
*50x
|-
 
|-
|-
|Ocular magnification
|-style="background:WhiteSmoke; color:black; vertical-align:middle; text-align:left;"
!Ocular
|10x
|10x
|10x
|10x
|No
|No
|10x
|10x
|10x
|10x
Line 51: Line 144:
|10x
|10x
|10x
|10x
|No
|10x
|10x
|10x
|10x
|10x
|10x
|-
|-
|Objective magnification
 
|2.5x, 5x, 10x, 20x, 50x
|Zoom 100x
|Zoom 80x
|5x, 10x, 20x, 50x, 100x
|2.5x, 5x, 10x, 20x, 50x
|5x, 10x, 20x, 50x
|5x, 10x, 20x, 50x, 100x
|2.5x, 5x, 20x, 50x
|Zoom 100x
|5x, 10x, 20x, 50x, 100x
|2.5x, 5x, 10x, 20x, 50x, 100x
|2.5x, 5x, 10x, 20x, 50x
|-
|-
|Bright field
|-style="background:LightGrey; color:black; vertical-align:middle; text-align:left;"
|Yes
!Special features
|No
|Stereoscopic microscope
|No
|IR imaging
|Yes
|
|Yes
|
|Yes
|
|Yes
*Motorized stage
|Yes
*'''[[Specific_Process_Knowledge/Characterization/Optical microscope/Nikon Eclipse L200 auto scan guide|Auto scan guide]]'''
|No
|
|Yes
|
|Yes
|
|Yes
|
|Stereoscopic microscope
|
|-
|-
|Dark field
 
|Yes
|No
|No
|Yes
|No
|Yes
|Yes
|No
|No
|Yes
|Yes
|Yes
|-
|-
|Polarizer
|-style="background:WhiteSmoke; color:black; vertical-align:middle; text-align:left;"
|Yes
!Contrast mechanisms
|No
|
|No
*Brightfield
|Yes
|
|No
*Polarizer
|No
*Brightfield
|Yes
|
|No
*Brightfield
|NO
*Darkfield
|Yes
|
|No
*Polarizer
|NO
*Brightfield
|
*Brightfield
*Darkfield
|
*Brightfield
*Darkfield
|
*Polarizer
*Brightfield
*Darkfield
|
*Polarizer
*Brightfield
*Darkfield
|
*Polarizer
*Brightfield
*Darkfield
|
*Brightfield
|
*Brightfield
*Darkfield
|-
|-
|Episcopic light (reflected light)
 
|Yes
|Yes
|Yes
|Yes
|Yes
|Yes
|Yes
|Yes
|Yes
|Yes
|Yes
|Yes
|-
|-
|Diascopic light (transmitted light)
|-style="background:LightGrey; color:black; vertical-align:middle; text-align:left;"
|No
!Illumination modes
|Yes
|
|No
*Episcopic
|No
|
|Yes
*Episcopic
|Yes
*Diascopic
|No
|
|Yes
*Episcopic
|No
*Diascopic
|No
|
|Yes
*Episcopic
|Yes
*Diascopic
|
*Episcopic
*Diascopic
|
*Episcopic
*Diascopic
|
*Episcopic
*Diascopic
|
*Episcopic
*Diascopic
|
*Episcopic
|
*Episcopic
|
*Episcopic
*Diascopic
|-
|-
|View with eye
 
|Yes
|Yes
|Yes
|Yes
|Yes
|Yes
|Yes
|Yes
|Yes
|Yes
|Yes
|Yes
|-
|-
|View on screen (camera)
|-style="background:WhiteSmoke; color:black; vertical-align:middle; text-align:left;"
|Yes
!Camera
|No
|None
|NO
|IR camera
|Yes
|DS-Fi2
|Yes
|None
|Yes
|DS-Fi1
|No
|DS-Fi1
|Yes
|
|No
*DS-Fi2
|Yes
*C-mount, 0.7x relay
|Yes
|
|Yes
*DS-Fi2
*C-mount, 0.7x relay
|DS-Fi2
|None
|Infinity X
|-
|-
|Measurement option
 
|No
|No
|No
|No
|NO
|Yes
|No
|No
|No
|No
|Yes
|Yes
|-
|-
|-style="background:LightGrey; color:black; vertical-align:middle; text-align:left;"
!Analysis software
|None
|None
|NIS-D
|None
|NIS-BR
|NIS-D
|NIS-D
|NIS-D
|NIS-D
|None
|DeltaPix
|-
|}
|}


<br clear="all" />


 
There are also two optical microscopes in building 451, a stereo microscope and a transmission microscope, that were both previously located in Packlab. Please ask staff / the BioMic group for details.
 
{| border="1" cellspacing="0" cellpadding="6"
!
! Zeiss (RR2)
! Leica (RR3)
! Leitz (RR4 Glassroom1)
! Zeiss (RR4 Glassroom1)
! Zeiss (RR4)
! Nikon (K10 yellow room)
|-
| Magnification
|25,50,100,
200,500x
|50,100,200,
500,1000x
|25,50,100,
200,500x
|50,100,200,
500,1000x
|25,50,100,
200,500x
|50,100,200,
500,1000x
|-
|Bright field
|yes
|yes
|yes
|yes
|yes
|yes
|-
| Dark field
|yes
|yes
|yes
|yes
|yes
|yes
|-
|Polarizer
|yes
|no
|no
|yes
|yes
|no
|-
|Episcopic light (reflected light)
|yes
|yes
|yes
|yes
|yes
|yes
|-
|Diascopic light (transmitted light)
|no
|yes
|yes
|no
|no
|yes
|-
|View with eye
|yes
|yes
|yes
|yes
|yes
|yes
|-
|View on screen
|no
|yes
|yes
|yes
|no
|yes
|-
|Measurement option
|no
|no
|yes
|yes
|no
|yes
|-
|}

Latest revision as of 13:14, 9 January 2026

The content on this page, including all images and pictures, was created by DTU Nanolab staff, unless otherwise stated.

Feedback to this page: click here

Nikon SMZ 1000 Noco IR Leica INM 100 Zeiss Jenatech Nikon Eclipse L200 #1 Nikon Eclipse L200 #2 Nikon Eclipse L200N #3 Nikon Eclipse L200N #4 Nikon ME 600 Leica S8 APO Zeiss Axiotron
Location 346-901 346-901 346-901 cleanroom
D-3?
cleanroom
D-3
cleanroom
A-1
cleanroom
D-3
cleanroom
E-5
cleanroom
F-1?
cleanroom
Cx1
cleanroom
F-3
Responsible group Wet chemistry Wet chemistry Wet chemistry Lithography Lithography Lithography Lithography Lithography Lithography Lithography Lithography
Objectives Zoom 0.8x - 8x
  • 2.5x
  • 10x
  • 20x
  • 50x
  • 2.5x
  • 5x
  • 10x
  • 20x
  • 50x
  • 5x
  • 10x
  • 20x
  • 50x
  • 100x
  • 2.5x
  • 5x
  • 10x
  • 20x
  • 50x
  • 2.5x
  • 5x
  • 10x
  • 20x
  • 50x
  • 100x
  • 2.5x
  • 5x
  • 10x
  • 20x
  • 50x
  • 100x
  • 2.5x
  • 5x
  • 10x
  • 20x
  • 50x
  • 100x
  • 5x
  • 10x
  • 20x
  • 50x
  • 100x
Zoom 1x - 8x
  • 5x
  • 10x
  • 20x
  • 50x
Ocular 10x 10x 10x 10x 10x 10x 10x 10x 10x 10x 10x
Special features Stereoscopic microscope IR imaging Stereoscopic microscope
Contrast mechanisms
  • Brightfield
  • Polarizer
  • Brightfield
  • Brightfield
  • Darkfield
  • Polarizer
  • Brightfield
  • Brightfield
  • Darkfield
  • Brightfield
  • Darkfield
  • Polarizer
  • Brightfield
  • Darkfield
  • Polarizer
  • Brightfield
  • Darkfield
  • Polarizer
  • Brightfield
  • Darkfield
  • Brightfield
  • Brightfield
  • Darkfield
Illumination modes
  • Episcopic
  • Episcopic
  • Diascopic
  • Episcopic
  • Diascopic
  • Episcopic
  • Diascopic
  • Episcopic
  • Diascopic
  • Episcopic
  • Diascopic
  • Episcopic
  • Diascopic
  • Episcopic
  • Diascopic
  • Episcopic
  • Episcopic
  • Episcopic
  • Diascopic
Camera None IR camera DS-Fi2 None DS-Fi1 DS-Fi1
  • DS-Fi2
  • C-mount, 0.7x relay
  • DS-Fi2
  • C-mount, 0.7x relay
DS-Fi2 None Infinity X
Analysis software None None NIS-D None NIS-BR NIS-D NIS-D NIS-D NIS-D None DeltaPix


There are also two optical microscopes in building 451, a stereo microscope and a transmission microscope, that were both previously located in Packlab. Please ask staff / the BioMic group for details.