LabAdviser/314/Preparation 314-307/Soft-matter: Difference between revisions
Appearance
mNo edit summary |
|||
| (93 intermediate revisions by 2 users not shown) | |||
| Line 2: | Line 2: | ||
'''Feedback to this page''': '''[mailto:labadviser@nanolab.dtu.dk?Subject=Feed%20back%20from%20page%20http://labadviser.nanolab.dtu.dk/index.php/LabAdviser/314/Preparation_314-307/Soft-matter click here]''' | '''Feedback to this page''': '''[mailto:labadviser@nanolab.dtu.dk?Subject=Feed%20back%20from%20page%20http://labadviser.nanolab.dtu.dk/index.php/LabAdviser/314/Preparation_314-307/Soft-matter click here]''' | ||
''This section is written by DTU Nanolab internal if nothing else is stated.'' | |||
[[Category:314]] | [[Category:314]] | ||
[[Category:314-Preparation]] | [[Category:314-Preparation]] | ||
| Line 14: | Line 15: | ||
[https://labmanager.dtu.dk/view_binary.php?class=MiscDocument&id=15&name=Leica_EM_GP2_Operating_manual.pdf Operating manual] ''- requires login''<br /> | |||
[[File:IMG_9460_GP2.jpg|400px|left|thumb|Leica EM GP2 Location at DTU Nanolab Building 307 Room 909B]]<br clear="all" /> | |||
[[File: | |||
For further information on the equipment usage or training contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | For further information on the equipment usage or training contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | ||
| Line 29: | Line 23: | ||
<br clear="all" /> | <br clear="all" /> | ||
= High Pressure Freezer = | |||
== Leica EM ICE | == Leica EM ICE == | ||
High pressure freezing is key for the study of intricate changes in fine structure or cellular dynamics. | High pressure freezing is key for the study of intricate changes in fine structure or cellular dynamics. | ||
* Cryo-immobilize your aqueous samples under high pressure with a unique freezing principle and uncover secrets of the cellular process. | * Cryo-immobilize your aqueous samples under high pressure with a unique freezing principle and uncover secrets of the cellular process. | ||
| Line 46: | Line 40: | ||
[[File:HPF EM ICE.jpg|600px|left|thumb|Leica EM ICE Location at DTU Nanolab Building 307]]<br clear="all" /> | [[File:HPF EM ICE.jpg|600px|left|thumb|Leica EM ICE Location at DTU Nanolab Building 307 Room 909B]]<br clear="all" /> | ||
For further information on the equipment usage or training contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | For further information on the equipment usage or training contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | ||
| Line 52: | Line 46: | ||
= Freeze substitution = | = Freeze substitution = | ||
== Leica EM AFS2 and EM FSP | == Leica EM AFS2 and EM FSP == | ||
The Leica EM AFS2 performs freeze substitution and progressive lowering of temperature (PLT) techniques and allows low temperature embedding and polymerization of resins. The Leica EM FSP (freeze substitution processor), an automatic reagent handling system combined with the Leica EM AFS2, dispenses reagents for both freeze substitution and PLT applications. The LED illumination from within the chamber and the attached stereomicroscope for viewing and positioning of samples ensures ease of use. | The Leica EM AFS2 performs freeze substitution and progressive lowering of temperature (PLT) techniques and allows low temperature embedding and polymerization of resins. The Leica EM FSP (freeze substitution processor), an automatic reagent handling system combined with the Leica EM AFS2, dispenses reagents for both freeze substitution and PLT applications. The LED illumination from within the chamber and the attached stereomicroscope for viewing and positioning of samples ensures ease of use. | ||
[[File:Freeze-substitution EM AFS2.jpg|300px|left|thumb|Leica EM AFS2 Location at DTU Nanolab Building 307]] | [[File:Freeze-substitution EM AFS2.jpg|300px|left|thumb|Leica EM AFS2 Location at DTU Nanolab Building 307 Room 909B]] | ||
[[File:EM FSP.JPG|200px|left|thumb|Leica EM FSP Location at DTU Nanolab Building 307]]<br clear="all" /> | [[File:EM FSP.JPG|200px|left|thumb|Leica EM FSP Location at DTU Nanolab Building 307 Room 909B]]<br clear="all" /> | ||
For further information on the equipment usage or training contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | For further information on the equipment usage or training contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | ||
<br clear="all" / | <br clear="all" /> | ||
= Microtome = | = Microtome = | ||
== Leica EM UC7 Ultramicrotome== | == Leica EM UC7 Ultramicrotome== | ||
The Ultramicrotome Leica EM UC7 provides easy sample preparation of ultrathin sections for TEM, SEM, AFM and LM application. It is suitable for highly skilled or absolute beginners. The Leica ultramicrotome can provide ultra thin sectioning of sample embedded in a resin/epoxy block with a feed range of 1 nm up to 15 µm. Glass or diamond knife can be used for the ultra sectioning of the samples. | The Ultramicrotome Leica EM UC7 provides easy sample preparation of ultrathin sections for TEM, SEM, AFM and LM application. It is suitable for highly skilled or absolute beginners. The Leica ultramicrotome can provide ultra thin sectioning of sample embedded in a resin/epoxy block with a feed range of 1 nm up to 15 µm. Glass or diamond knife can be used for the ultra sectioning of the samples. | ||
[https://labmanager.dtu.dk/view_binary.php?class=MiscDocument&id=15&name=EM_UC7_Operating_manual.pdf Operating manual] ''-requires login''<br /> | |||
[[File:IMG_9461_UC7.jpg|400px|left|thumb|Leica EM UC7 Location at DTU Nanolab Building 307 Room 906]]<br clear="all" /> | |||
'''Requirement for training:''' | |||
* Completion of the DTU Epoxy course | |||
* Purchased of own diamond knife. | |||
For further information about the equipment usage or training contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | |||
<br clear="all" /> | <br clear="all" /> | ||
| Line 98: | Line 78: | ||
[https://labmanager.dtu.dk/view_binary.php?class=MiscDocument&id=15&name=EM_FC7_Operating_manual.pdf Operating manual] ''- requires login''<br /> | |||
[[File:Leica EM FC7 Cryo-Ultramicrotome.jpg|400px|left|thumb|Leica EM FC7 Location at DTU Nanolab Building 307 Room 906]]<br clear="all" /> | |||
'''Requirement for training:''' | |||
* Purchased of own diamond knife. | |||
For further information about the equipment usage or training contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | |||
<br clear="all" /> | <br clear="all" /> | ||
= KnifeMaker= | = KnifeMaker= | ||
== | == Leica EM KMR3 == | ||
At DTU Nanolab we offer the possibility to make glass knives for ultramicrotomy applications using the | At DTU Nanolab we offer the possibility to make glass knives for ultramicrotomy applications using the Leica EM KMR3 Knifemaker. | ||
[[File: | [[File:IMG_9462_KMR3.jpg|400px|thumb|left|LKB Knifemaker Location at DTU Nanolab Building 307 Room 909B]]<br clear="all" /> | ||
For further information about the knifemaker usage and training contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | For further information about the knifemaker usage and training contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | ||
| Line 140: | Line 111: | ||
[https://labmanager.dtu.dk/view_binary.php?class=MiscDocument&id=15&name=EM_CPD300_Operating_manual_small.pdf Operating manual] ''- requires login'' <br /> | |||
[[File: | [[File:IMG_9456_CPD300.jpg|400px|thumb|left|Leica EM CPD300 Location at DTU Nanolab Building 307 Room 903]]<br clear="all" /> | ||
For further information on the CPD usage or training contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | For further information on the CPD usage or training contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | ||
<br clear="all" /> | <br clear="all" /> | ||
= | = Coater = | ||
The | == Leica EM ACE600 == | ||
The coater offers 3 applications | |||
* Platinum coating | |||
* Glow discharge | |||
* | * Carbon coating | ||
* | |||
* | |||
[[File:IMG_9459_ACE600.jpg|400px|thumb|left|Leica EM ACE600 Location at DTU Nanolab Building 307 Room 907]]<br clear="all" /> | |||
For further information about the coater usage and training contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | |||
[[File: | |||
For further information | |||
<br clear="all" /> | <br clear="all" /> | ||
| Line 182: | Line 144: | ||
* Cold room and incubator compatible | * Cold room and incubator compatible | ||
[[File:IMG_9636.jpg|400px|thumb|left|Mini tube rotator Location at DTU Nanolab Building | [[File:IMG_9636.jpg|400px|thumb|left|Mini tube rotator Location at DTU Nanolab Building 307 Room 903]]<br clear="all" /> | ||
For further information on the equipment usage contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | For further information on the equipment usage contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | ||
<br clear="all" /> | <br clear="all" /> | ||
== Centrifuge 5430R == | |||
Two rotor are available for this centrifuge in the Softmatter lab. | |||
* Rotor FA-45-30-11 | |||
Allows max. capacity 30 micro test tubes for 1.5/ | |||
2.0 mL and operates at 25000 ×g /15350 rpm | |||
* Rotor F-35-6-30 | |||
Allows max. capacity 6 conical tubes for 50 mL or 6 conical tubes for 15 mL and operates at 7745 ×g /7830 rpm | |||
'''Specifications:''' | |||
'''Specifications:''' | |||
* Max. rotor capacity depending on type of rotor: 30 × 1.5/2.0 mL, 6 × 50 mL, 6 × 15 mL | |||
* Max. speed: 25000 ×g (15350 rpm) | |||
* Acceleration/braking time: <25/25 s | |||
* Temperature range: -11 °C to +40 °C | |||
* Run time: 30 s to 99:59 h, infinity | |||
[https://www.eppendorf.com/product-media/doc/en/335227/Centrifugation_Operating-manual_Centrifuge-5430-R.pdf Instruction manual] ''- requires login'' [[File:IMG_9457_Centrifuge 5430R.jpg|400px|thumb|left|Eppendorf centrifuge 5430R Location at DTU Nanolab Building 307 Room 903]]<br clear="all" /> | |||
For further information on the equipment usage contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | |||
<br clear="all" /> | |||
== Mini Centrifuge == | |||
The Eppendorf Mini Spin plus centrifuge is a desktop centrifuge and has a user friendly digital display for time and speed. | |||
Specifications: | |||
* Max. capacity 12 x 1.5/2.0 mL | |||
* Max. RCF 14 100 g | |||
* Speed 800 - 14 500 rpm (100 rpm steps) | |||
* Acceleration time 13 s | |||
* Timer 15 s to 99 mins | |||
[[File:Mini Spin centrifuge.jpg|400px|thumb|left|Eppendorf Mini Spin centrifuge Location at DTU Nanolab Building | [https://labmanager.dtu.dk/view_binary.php?class=MiscDocument&id=15&name=Eppendorf_Mini_Spin_plus_centrifuge_Original_Instructions.pdf Instruction manual] ''- requires login'' <br />[[File:Mini Spin centrifuge.jpg|400px|thumb|left|Eppendorf Mini Spin centrifuge Location at DTU Nanolab Building 307 Room 903]]<br clear="all" /> | ||
For further information on the equipment usage contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | For further information on the equipment usage contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | ||
| Line 201: | Line 193: | ||
== Magnetic stirrer == | == Magnetic stirrer == | ||
The myPlate magnetic stirrer is ideal for homogeneous mixing chemicals | The myPlate magnetic stirrer is ideal for homogeneous mixing of chemicals. | ||
| Line 207: | Line 199: | ||
*High chemical resistance | *High chemical resistance | ||
*Can be used at 5 to 40 °C (80% relative humidity), in an incubator or cold room | *Can be used at 5 to 40 °C (80% relative humidity), in an incubator or cold room | ||
*Speed range (min-1) | *Speed range 100 to 2500 (min-1) | ||
[[File:myPlate magnetic stirrer.jpg|400px|thumb|left|myPlate magnetic stirrer Location at DTU Nanolab Building | |||
[[File:myPlate magnetic stirrer.jpg|400px|thumb|left|myPlate magnetic stirrer Location at DTU Nanolab Building 307 Room 903]]<br clear="all" /> | |||
For further information on the equipment usage contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | For further information on the equipment usage contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | ||
| Line 216: | Line 209: | ||
== Pulsing Vortex Mixer == | == Pulsing Vortex Mixer == | ||
The VWR pulsing vortex mixer | The VWR pulsing vortex mixer provides ideal mixing of solutions or chemicals. | ||
| Line 224: | Line 217: | ||
* Have timer from 1 s to 160 h | * Have timer from 1 s to 160 h | ||
[[File:IMG_9635.jpg|400px|thumb|left|VWR Pulsing Vortex Mixer Location at DTU Nanolab Building | [https://labmanager.dtu.dk/view_binary.php?class=MiscDocument&id=15&name=VWR_pulsing_vortex_mixer_Instruction_Manual.pdf Instruction manual] ''- requires login'' <br /> | ||
[[File:IMG_9635.jpg|400px|thumb|left|VWR Pulsing Vortex Mixer Location at DTU Nanolab Building 307 Room 903]]<br clear="all" /> | |||
For further information on the equipment usage contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | For further information on the equipment usage contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | ||
| Line 233: | Line 227: | ||
== Magnetic hotplate stirrer == | == Magnetic hotplate stirrer == | ||
VWR Professional hotplate | VWR Professional hotplate stirrer is ideal for stirring chemicals with controlled high temperature. An external resistance thermometer (RTD) probe option is available for temperature control of the sample. | ||
| Line 245: | Line 239: | ||
[[File:Magnetic hotplate stirrer.jpeg|400px|thumb|left|VWR Magnetic hotplate stirrer Location at DTU Nanolab Building 307 Room 903]]<br clear="all" /> | |||
[[File:Magnetic hotplate stirrer.jpeg|400px|thumb|left|VWR Magnetic hotplate stirrer Location at DTU Nanolab Building | |||
For further information on the equipment usage contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | For further information on the equipment usage contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | ||
| Line 254: | Line 246: | ||
== Hotplate == | == Hotplate == | ||
VWR Hotplate W10 is suitable for drying paraffin sections on slides or for de-icing tools when doing cryo experiments | VWR Hotplate W10 is suitable for drying paraffin sections on microscope slides or for de-icing tools when doing cryo experiments. | ||
Specifications: | |||
*Electronic touch display | *Electronic touch display | ||
*Sleek and compact | *Sleek and compact | ||
*Ideal size for drying up to 40 slides | *Ideal size for drying up to 40 microscope slides | ||
*Temperature range between ambient and +89 °C | *Temperature range between ambient and +89 °C | ||
*Digital thermostat | *Digital thermostat | ||
[https://labmanager.dtu.dk/view_binary.php?class=MiscDocument&id=15&name=VWR_Hotplate_W10_Instruction_Manual.pdf Instruction manual] ''- requires login'' <br /> | |||
[[File:VWR Hotplate W10.jpg|400px|thumb|left|VWR Hotplate W10 Location at DTU Nanolab Building | [[File:VWR Hotplate W10.jpg|400px|thumb|left|VWR Hotplate W10 Location at DTU Nanolab Building 307 Room 903]]<br clear="all" /> | ||
For further information on the equipment usage contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | For further information on the equipment usage contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | ||
| Line 274: | Line 267: | ||
== Analytical balance PX224 == | == Analytical balance PX224 == | ||
The Ohaus Pioneer PX224 | The Ohaus Pioneer PX224 offers high accuracy and repeatability weight measurements. | ||
Specifications: | |||
*Weighing capacity is 220 g | *Weighing capacity is 220 g | ||
*Readability is 0.1 mg | *Readability is 0.1 mg | ||
| Line 285: | Line 279: | ||
[[File: | [[File:IMG_9463_Analytical balance.jpg|400px|thumb|left|Ohaus PX224 analytical balance Location at DTU Nanolab Building 307 Room 903]]<br clear="all" /> | ||
For further information on the equipment usage contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | |||
<br clear="all" /> | |||
== Midi 40 CO2 Incubator == | |||
The incubator is suitable for the incubation of cell culture and operates at temperatures ranging from 5°C above ambient temperature to 50°C ±0.2°C. | |||
Specifications: | |||
* Temperature range is from ambient +5° to 50°C ±0.2°C | |||
* Relative Humidity is <90% at 37°C | |||
* CO2 Sensor is TC Sensor | |||
* Capacity is 40L | |||
[[File:Midi 40 CO2 Incubator.jpg|400px|thumb|left|Midi 40 CO2 Incubator Location at DTU Nanolab Building 307 Room 903]]<br clear="all" /> | |||
For further information on the equipment usage contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | |||
<br clear="all" /> | |||
== Ultrasonic cleaner == | |||
The GT SONIC ultrasonic cleaner can be used to remove dirt, grease, corrosion or cleaning electronic and small mechanical parts. Millions of tiny bubbles are created when ultrasonic sound is passed through liquid. These tiny bubbles combined with a huge pressure create incredible cleaning results. | |||
Specifications: | |||
* Temperature range is from 30°C to 80°C | |||
* Timer can be set from 1 to 99 minutes | |||
* Capacity is 2L | |||
Four modes are available on the intrument and are as follows: | |||
* '''Degas mode''' - This mode is to be used after a fluid change to rapidly remove air from the fluid so it can provide maximum cleaning effectiveness from the start of the cleaning cycle. | |||
* '''Delicate mode''' - The cleaner runs at half power which provides a less aggressive cleaning action for fragile/delicate items. | |||
* '''Full-power mode''' - A powerful deep clean that will clean heavily contaminated items. | |||
* '''Temperature and Timing mode''' - Allows the user to set both the fluid temperature and duration of the cleaning cycle. These parameters will change depending on the cleaning agent and item being cleaned. | |||
[[File:Ultrasonic cleaner.jpg|400px|thumb|left|GT SONIC Ultrasonic cleaner Location at DTU Nanolab Building 307 Room 903]]<br clear="all" /> | |||
For further information on the equipment usage contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | For further information on the equipment usage contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | ||
<br clear="all" /> | <br clear="all" /> | ||
== | == Drying oven == | ||
The TS9026 drying oven is of 26L capacity and is used for epoxy embedding experiments. | |||
Specifications: | |||
* Temperature range is from ambient to 250°C | |||
* Fan speed is 0 to 10 | |||
* Capacity is 26L | |||
[[File: | [[File:IMG 9634.jpg|400px|thumb|left|TS9026 Drying oven Location at DTU Nanolab Building 307 Room 903]]<br clear="all" /> | ||
For further information on the equipment usage contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | For further information on the equipment usage contact mktracy@dtu.dk [https://www.dtu.dk/english/service/phonebook/person?id=141983&cpid=260636&tab=0]. | ||