Specific Process Knowledge/Wafer cleaning/RCA: Difference between revisions
Appearance
No edit summary |
|||
| Line 3: | Line 3: | ||
The RCA clean is used for cleaning the wafers before taking them into the furnaces and a few other equipments (check the cross contamination sheet). | The RCA clean is used for cleaning the wafers before taking them into the furnaces and a few other equipments (check the cross contamination sheet). | ||
It consists of two solutions: RCA1 and RCA2 plus diluted HF. A crucial part of the RCA clean is the oxidation by H< | It consists of two solutions: RCA1 and RCA2 plus diluted HF. A crucial part of the RCA clean is the oxidation by H<sub>2</sub>O<sub>2</sub>. Therefore the life time of the RCA solutions are limited by the presence of the H<sub>2</sub>O<sub>2</sub> which is highly volatile at 70 <sup>o</sup>C. | ||
*The RCA1 contains: H< | *The RCA1 contains: H<sub>2</sub>O, NH<sub>4</sub>OH and H<sub>2</sub>O<sub>2<sub> (5:1:1). It is used for removal of light organics, particles and metals. <br \> | ||
*The RCA2 contains: H< | *The RCA2 contains: H<sub>2</sub>O, HCl and H<sub>2</sub>O<sub>2</sub> (5:1:1). It is used for removal of alkalis, metal hydroxides, and residual metals. | ||
===RCA procedure=== | ===RCA procedure=== | ||
| Line 36: | Line 36: | ||
|- | |- | ||
|'''Chemical solution''' | |'''Chemical solution''' | ||
|H< | |H<sub>2</sub>O, NH<sub>4</sub>OH(25-29%) and H<sub>2</sub>O<sub>2</sub>(30%) (5:1:1) | ||
|H< | |H<sub>2</sub>O, HCl(37%) and H<sub>2</sub>O<sub>2</sub>(30%) (5:1:1) | ||
|5% | |5% H2 | ||
|- | |- | ||
|'''Process temperature''' | |'''Process temperature''' | ||