Jump to content

Specific Process Knowledge/Lithography/Aligners/MAvsMLA: Difference between revisions

From LabAdviser
Taran (talk | contribs)
Taran (talk | contribs)
Line 17: Line 17:
==AZ 5214E==
==AZ 5214E==
===Resolution and yield===
===Resolution and yield===
* Aligner: Maskless 02 (MLA2)
* Table with optimal parameters and resolution for different aligners
* Aligner: MA6-2
* Wafer maps of:
* Aligner: MA6-1
** Aligner: Maskless 02 (MLA2)
** Aligner: MA6-1
** Aligner: MA6-2 before service
** Aligner: MA6-2 after service + WEC pressure


===Resist profile (sidewall angle and linewidth)===
===Resist profile (sidewall angle and linewidth)===

Revision as of 17:19, 8 June 2026

The content on this page, including all images and pictures, was created by DTU Nanolab staff, unless otherwise stated.

Feedback to this page: click here

Slides presented at NNUM in Uppsala 2026

MA6 vs MLA 2026_v09

Additional data

THIS PAGE IS UNDER CONSTRUCTION

AZ 5214E

Resolution and yield

  • Table with optimal parameters and resolution for different aligners
  • Wafer maps of:
    • Aligner: Maskless 02 (MLA2)
    • Aligner: MA6-1
    • Aligner: MA6-2 before service
    • Aligner: MA6-2 after service + WEC pressure

Resist profile (sidewall angle and linewidth)

Width of 2µm line vs. exposure dose for 1.5µm AZ 5214E.
Blue circles: Exposed on Aligner: MA6-2 in vacuum contact.
Orange Squares: Exposed on Aligner: Maskless 02 (MLA2) using defoc 2 (QC defoc=2).
Sidewall angle vs. exposure dose for 1.5µm AZ 5214E.
Blue circles: Exposed on Aligner: MA6-2 in vacuum contact.
Orange Squares: Exposed on Aligner: Maskless 02 (MLA2) using defoc 2 (QC defoc=2).
Linewidth and sidewall angle vs. defocus value for 1.5µm AZ 5214E exposed in Aligner: Maskless 02 (MLA2) using dose 95mJ/cm2.
Blue circles: Width of 2µm line. Orange Squares: Sidewall angle.


AZ MiR 701

Resolution

Resist profile (sidewall angle and linewidth)

Width of 2µm line vs. exposure dose for 1.5µm AZ MiR 701.
Blue circles: Exposed on Aligner: MA6-2 in vacuum contact.
Orange Squares: Exposed on Aligner: Maskless 02 (MLA2) using defoc 2 (QC defoc=2).
Sidewall angle vs. exposure dose for 1.5µm AZ MiR 701.
Blue circles: Exposed on Aligner: MA6-2 in vacuum contact.
Orange Squares: Exposed on Aligner: Maskless 02 (MLA2) using defoc 2 (QC defoc=2).
Linewidth and sidewall angle vs. defocus value for 1.5µm AZ MiR 701 exposed in Aligner: Maskless 02 (MLA2) using dose 275mJ/cm2.
Blue circles: Width of 2µm line. Orange Squares: Sidewall angle.


AZ nLOF 2020

Resolution

Resist profile (sidewall angle and linewidth)

Width of 2µm line vs. exposure dose for 2µm AZ nLOF 2020.
Blue circles: Exposed on Aligner: MA6-2 in vacuum contact.
Orange Squares: Exposed on Aligner: Maskless 01 (MLA1) using defoc -4 (QC defoc=-2).
Grey triangles: Exposed on Aligner: Maskless 02 (MLA2) using defoc 0 (QC defoc=2).
Sidewall angle vs. exposure dose for 2µm AZ nLOF 2020.
Blue circles: Exposed on Aligner: MA6-2 in vacuum contact.
Orange Squares: Exposed on Aligner: Maskless 01 (MLA1) using defoc -4 (QC defoc=-2).
Grey triangles: Exposed on Aligner: Maskless 02 (MLA2) using defoc 0 (QC defoc=2).
Linewidth and sidewall angle vs. defocus value for 2µm AZ nLOF exposed in Aligner: Maskless 01 (MLA1) using dose 220mJ/cm2.
Blue circles: Width of 2µm line. Orange Squares: Sidewall angle.
Linewidth and sidewall angle vs. defocus value for 2µm AZ nLOF exposed in Aligner: Maskless 02 (MLA2) using dose 450mJ/cm2.
Blue circles: Width of 2µm line. Orange Squares: Sidewall angle.