==Barc Etch==
==Barc Etch==



Latest revision as of 15:54, 6 February 2023

Feedback to this page: click here
Unless otherwise stated, this page is written by DTU Nanolab internal

Barc Etch

Etching barc with a CF4 recipe for barc etching is a good idea if you are on the limit of having enough DUV resist mask to reach etch depth you need. Here is an example of a barc etch I have started testing. I have also tried with and O2 descum process for comparison.

Parameter Barc etch with CF4 Barc etch with O2
Coil power 800W 120w
Platen power 100W 15W
Pressure 3 mTorr 5mTorr
Flow rate CF4 4 sccm
Flow rate H2 20sccm
Flow rate O2 10sccm
T 0 degrees 0 degrees


Parameter Results with 'Barc etch with CF' Results with 'Barc etch with O2'
Etch rate in barc 52 nm in 30s [bghe 20150519] 62 nm in 50s [bghe 20150521]
Etch rate in KRF resist 27 nm in 30s [bghe 20150519] 73 nm in 50s [bghe 20150521]
Selectivity KRF:Barc 1:2 1:0.8
Etch 65nm barc Use 40-45s Use 55-60s