Specific Process Knowledge/Lithography/ARN8200: Difference between revisions
Line 5: | Line 5: | ||
Allresist also provides these [https://www.allresist.com/wp-content/uploads/sites/2/2020/03/SXAR-N8200-1_english_Allresist_product_information.pdf processing guidelines.] | Allresist also provides these [https://www.allresist.com/wp-content/uploads/sites/2/2020/03/SXAR-N8200-1_english_Allresist_product_information.pdf processing guidelines.] | ||
== Contrast curve == | == Contrast curve @ 100 kV (JEOL 9500) == | ||
Exposure dose for AR-N 8200 is very dependent on Post Exposure Bake (PEB) temperature. A contrast curve for four different PEB processes were obtained with the following process parameters. | Exposure dose for AR-N 8200 is very dependent on Post Exposure Bake (PEB) temperature. A contrast curve for four different PEB processes were obtained with the following process parameters. |
Revision as of 10:25, 8 August 2022
AR-N 8200
AR-N 8200 is a negative E-beam resist from Allresist, it is also known as "Medusa 82". A product presentation from Allresist is available here AR-N8200 presentation.
Allresist also provides these processing guidelines.
Contrast curve @ 100 kV (JEOL 9500)
Exposure dose for AR-N 8200 is very dependent on Post Exposure Bake (PEB) temperature. A contrast curve for four different PEB processes were obtained with the following process parameters.
AR-N 8200 Contrast Curve, Processed by THOPE, FEB 2022 | ||||
---|---|---|---|---|
Resist | Spin Coat | E-beam exposure | PEB | Development |
AR-N8200.06 | LabSpin 2, 4000 rpm for 60s, softbake 10 min @ 150 degC, thickness is 110 nm | JBX9500, 60 nA, doses 100-1600 µC/cm2, 150 µm x 300 µm rectangles | Labspin 2 hotplate, 130, 150, 160 or 170 degC for 10 min | EBL development fumehood, 60 sec development in AR300-47:DIW (1:1), 30 sec rinse in DIW, nitrogen gun dry |
Hotplate temperatures are assumed surface temperatures based on the 0.90 correction factor in use on the hotplate.
The resulting resist structure height is mapped with Dektak XTa and plotted as a contrast curve below. It is apparent that the dose and contrast is very dependent on the PEB parameters.