Specific Process Knowledge/Characterization/Optical microscope: Difference between revisions
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
=<span style="background:#FF2800">THIS PAGE IS UNDER CONSTRUCTION</span>[[image:Under_construction.png|200px]]= | |||
'''Feedback to this page''': '''[mailto:labadviser@nanolab.dtu.dk?Subject=Feed%20back%20from%20page%20http://labadviser.nanolab.dtu.dk/index.php/Specific_Process_Knowledge/Characterization/Optical_microscope click here]''' | '''Feedback to this page''': '''[mailto:labadviser@nanolab.dtu.dk?Subject=Feed%20back%20from%20page%20http://labadviser.nanolab.dtu.dk/index.php/Specific_Process_Knowledge/Characterization/Optical_microscope click here]''' | ||
Line 230: | Line 231: | ||
It is possible to make an automated scanning of a full wafer on the Nikon Eclipse L200 with motorized stage '''[[Specific_Process_Knowledge/Characterization/Optical microscope/Nikon Eclipse L200 auto scan guide|Nikon Eclipse L200 auto scan guide]]''' | It is possible to make an automated scanning of a full wafer on the Nikon Eclipse L200 with motorized stage '''[[Specific_Process_Knowledge/Characterization/Optical microscope/Nikon Eclipse L200 auto scan guide|Nikon Eclipse L200 auto scan guide]]''' | ||
{|border="1" cellspacing="1" cellpadding="3" style="text-align:left;" | |||
|- | |||
|- | |||
|-style="background:white; color:black; vertical-align:middle; text-align:center" | |||
| | |||
!Nikon SMZ 1000 | |||
!Nikon SMZ 1000 | |||
|- | |||
|- | |||
|-style="background:white; color:black;" | |||
!Image | |||
|[[image:Nikon SMZ 1000.jpg|100x100px|thumb|center]] | |||
|[[image:Nikon SMZ 1000.jpg|100x100px|thumb|center]] | |||
|- | |||
|- | |||
|-style="background:LightGrey; color:black; vertical-align:middle;" | |||
!RowHeader1 | |||
| | |||
| | |||
|- | |||
|- | |||
|-style="background:WhiteSmoke; color:black; vertical-align:middle;" | |||
!RowHeader2 | |||
| | |||
| | |||
|- | |||
|} | |||
<br clear="all" /> |
Revision as of 15:10, 2 April 2020
THIS PAGE IS UNDER CONSTRUCTION
Feedback to this page: click here
Zeiss Jenatech (strain) | Nikon SMZ 1500 | Leica S8 APO | Leitz Medilux | Zeiss Axiotron 2 | Zeiss Jenatech (particles measurements) | Noco IR microscope | Nikon SMZ 1000 | Nikon ME 600 | Nikon Eclipse L200 | Nikon Eclipse L200 (2) | Nikon ECLIPSE L200N 3 | Nikon ECLIPSE L200N 4 | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Location | Check LabManager | Check LabManager | Check LabManager | Check LabManager | Check LabManager | Check LabManager | Check LabManager | Check LabManager | Check LabManager | Check LabManager | Check LabManager | Check LabManager | Check LabManager |
Special features | Wollastron prism | Stereoscopic microscope | Stereoscopic microscope | No | No | No | Infra red (IR) camera | Stereoscopic microscope | Wollastron prism | Motorized stage | No | No | No |
Ocular magnification | 10x | No | No | 10x | 10x | 10x | 10x | No | 10x | 10x | 10x | 10x | 10x |
Objective magnification | 2.5x, 5x, 10x, 20x, 50x | Zoom 100x | Zoom 80x | 2.5x, 5x, 10x, 20x, 50x | 5x, 10x, 20x, 50x | 5x, 10x, 20x, 50x, 100x | 2.5x, 5x, 20x, 50x | Zoom 100x | 5x, 10x, 20x, 50x, 100x | 2.5x, 5x, 10x, 20x, 50x, 100x | 2.5x, 5x, 10x, 20x, 50x, 100x | 2.5x, 5x, 10x, 20x, 50x, 100x | 2.5x, 5x, 10x, 20x, 50x, 100x |
Bright field | Yes | No | No | Yes | Yes | Yes | Yes | No | Yes | Yes | Yes | Yes | Yes |
Dark field | Yes | No | No | No | Yes | Yes | No | No | Yes | Yes | Yes | Yes | Yes |
Polarizer | Yes | No | No | No | No | Yes | No | No | Yes | No | No | No | No |
Episcopic light (reflected light) | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Diascopic light (transmitted light) | No | Yes | No | Yes | Yes | No | Yes | No | No | Yes | Yes | Yes | Yes |
View with eye | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
View on screen (camera) | Yes | No | No | Yes | Yes | No | Yes (IR) | No | Yes | Yes | Yes | Yes | Yes |
Measurement option | No | No | No | No | Yes | No | No | No | No | Yes | Yes | Yes | Yes |
It is possible to make an automated scanning of a full wafer on the Nikon Eclipse L200 with motorized stage Nikon Eclipse L200 auto scan guide
Nikon SMZ 1000 | Nikon SMZ 1000 | |
---|---|---|
Image | ||
RowHeader1 | ||
RowHeader2 |