LabAdviser: Difference between revisions

From LabAdviser
Bghe (talk | contribs)
Bghe (talk | contribs)
No edit summary
Line 11: Line 11:


'''News in LabAdviser:''' <br/>
'''News in LabAdviser:''' <br/>
*The latest monthly LabAdviser update: [[Media:Monthly_LabAdviser_update_20181116.docx|LabAdviser update send out 2018-11-16]] <br>
*The latest monthly LabAdviser update: [[Media:Monthly_LabAdviser_update_20190128.docx|LabAdviser update send out 2019-01-28]] <br>
<!-- Slides from the customer meeting December 2016: [[media:Stormode 2016.pdf|2016 Customer meeting]] -->
<!-- Slides from the customer meeting December 2016: [[media:Stormode 2016.pdf|2016 Customer meeting]] -->
*Slides from the latest Tech Forum are here: [[media:Techforum 2018_3.pdf|Tech_Forum_2018_3]]
*Slides from the latest Tech Forum are here: [[media:Techforum 2018_3.pdf|Tech_Forum_2018_3]]

Revision as of 13:38, 28 January 2019

LabAdviser is a wiki that contains information about

  • equipment at DTU Nanolab that covers micro and nano fabrication in the cleanroom facility in building 346 and surroundings (in building 346 and 347) and characterization equipment, primarily electron microscopy at CEN building 314 and surroundings.
  • fabrication steps in micro and nano fabrication that takes place at the cleanroom fabrication facility and surroundings and
  • electron microscopy methods that takes place at the Characterization facility (CEN).

An overview of the equipment in these facilities can be found and some fabrication process flows and singles fabrication steps are described. In general LabAdviser is meant to advise you to the right equipment and to advise you to a good starting point for your micro and nano fabrication steps as for your electron microscopy work. This should not be replacing communication with the staff of the facilities but we recommend it as a good starting point before contacting the staff. To enter LabAdviser you need to log in with your DTU login. LabAdviser is only editable for the staff of the facilities. If you need further information about certain machinery or processes, please contact the relevant staff. Any feedback or input you might have to LabAdviser is welcome and can be given by mail to the LabAdviser mailbox: labadviser@danchip.dtu.dk


News in LabAdviser:


Contents




Overview of micro and nano fabrication steps - a guide to where you can find fabrication information in LabAdviser:

- - -
Clean your sample Dry your sample Create a thin film on your sample Dope your sample
Thermal treatment of your sample Make a mask on your sample Transfer pattern to your sample Define your structure directly
Bond your samples together Characterize your sample Pack your sample Process flow examples


Contact Information for the DTU Nanolab fabrication part

In order to get the quickest response to training requests, process approvals, questions etc. please use the following mailboxes to DTU Nanolab (formerly known as Danchip).

Subject Email Description
Training and Process Flow training@nanolab.dtu.dk All requests regarding equipment training and process flows. Please add your Name to the subject line.

Note: Requests are commonly answered within 2 workdays.
E-beam training e-beam@nanolab.dtu.dk Requests regarding training on JEOL JBX-9500FSZ or Raith Eline e-beam systems. Please study the material on the EBL Labadviser pages beforehand.
E-beam Cassette loading e-beamload@nanolab.dtu.dk Requests regarding cassette loading on JEOL JBX-9500FSZ.
General inquiries nanolabsupport@nanolab.dtu.dk Inquiries related to machines, cleanroom access, Mask review, tool changes, and others. Please add your Name to the subject line.

Note: Requests are commonly answered within 2 workdays.
Metal Wishes metal@nanolab.dtu.dk Requests for change of metal in Thin Film Deposition equipment.
See current and future materials in statuslog of the respective machines.


Lesker - status log
E-Beam Evaporator (Temescal) - status log
E-Beam Evaporator (10-pockets) - status log
Sputter-System Metal-Oxide(PC1) - status log
Sputter-System Metal-Nitride(PC3) - logbook

For requests regarding Wordentec, please contact the Thin Film group directly.

Gas-related Requests DCH-Gas@nanolab.dtu.dk All topics gas-related (issues, information regarding ordering, delivery, changing etc). Mostly for internal DTU Nanolab use.
LabAdviser Mailbox labadviser@nanolab.dtu.dk Any questions or feedback to LabAdviser.
Commercial Inquiries sales@nanolab.dtu.dk For all inquiries regarding in-sourcing, commercial applications, rent of cleanroom space, etc


DTU Nanolab Fabrication Cleanroom Naming and Phone Numbers



Room number Where in the room Phone number
A-1 At III-V RIE 55 804
Ax2 At the Lesker 55 815
A-5 In the corner near the furnace/plasma asher 55 803
B-1 In the corridor 55 806
C-1 At the corridor 55 808
D-1 The entrance room 55 703
D-3 At the KOH 55 940
E-1 By the e-beam computers 55 943
E-5 By Inclined UV-lamp 55 946
E-6 Furnace 6" 55 948
F-1 III-V growth 55 949
F-2 Next to Dektak-XTA 55 941
F-3 DUV Stepper 55 947
901 Injection molder room in the basement 55 812


DTU Nanolab Characterization Facility and Phone Numbers




Room number Description Phone number
314-011 Quanta FEG 56 406
314-014 Tecnai 56 407
314-033 Prep room No phone
314-034 Inspect S 56 414
314-037 Titan ETEM 56 408
314-040 Prep room (Bio) 56 413
314-042 Titan ATEM 56 409
314-060 Nova 56 412
314-061 Helios 56 411