The results in the table below show that the errors are at or below the measurement uncertainty for the stitching tests using no flat alignment.  
The results in the table below show that the errors are at or below the measurement uncertainty for the stitching tests using no flat alignment.  
<br/>When flat alignment is used, a rotation error of ~1.5ppm appears, along with a ~0.3µm shift and a +6ppm scaling of the Y axis. This is the level of accuracy we can expect when the rotation compensation is applied, i.e. when aligning to a previously printed layer.
<br/>When flat alignment is used, a rotation error of ~1.5ppm appears, along with a ~0.3µm misalignment and a +6ppm scaling of the Y axis. This is the level of accuracy we can expect when the rotation compensation is applied, i.e. when aligning to a previously printed layer.