Specific Process Knowledge/Wafer cleaning/RCA: Difference between revisions
Appearance
| Line 3: | Line 3: | ||
The RCA clean is used for cleaning the wafers before taking them into the furnaces and a few other equipments (check the cross contamination sheet). | The RCA clean is used for cleaning the wafers before taking them into the furnaces and a few other equipments (check the cross contamination sheet). | ||
It consists of two solutions: RCA1 and RCA2 plus diluted HF. A crucial part of the RCA clean is the oxidation by H<math>_2</math>O<math>_2</math>. Therefore the life time of the RCA solutions are limited by the presence of the H<math>_2</math>O<math>_2</math> which is highly volatile at 70 < | It consists of two solutions: RCA1 and RCA2 plus diluted HF. A crucial part of the RCA clean is the oxidation by H<math>_2</math>O<math>_2</math>. Therefore the life time of the RCA solutions are limited by the presence of the H<math>_2</math>O<math>_2</math> which is highly volatile at 70 <sup>o</sup>C. | ||
*The RCA1 contains: H<math>_2</math>O, NH<math>_4</math>OH and H<math>_2</math>O<math>_2</math> (5:1:1). It is used for removal of light organics, particles and metal. <br \> | *The RCA1 contains: H<math>_2</math>O, NH<math>_4</math>OH and H<math>_2</math>O<math>_2</math> (5:1:1). It is used for removal of light organics, particles and metal. <br \> | ||