Specific Process Knowledge/Characterization/Topographic measurement: Difference between revisions

From LabAdviser
Bghe (talk | contribs)
Knil (talk | contribs)
Line 25: Line 25:
![[Specific Process Knowledge/Characterization/Profiler#Optical_Profiler_(Sensofar)|Optical Profiler (Sensofar)]]
![[Specific Process Knowledge/Characterization/Profiler#Optical_Profiler_(Sensofar)|Optical Profiler (Sensofar)]]
![[Specific Process Knowledge/Characterization/AFM: Atomic Force Microscopy|Nanoman]]
![[Specific Process Knowledge/Characterization/AFM: Atomic Force Microscopy|Nanoman]]
![[Specific Process Knowledge/Characterization/Profiler#Dektak III-V Profiler|Dektak III-V Profiler]]
|-
|-


Line 34: Line 35:
|3D Profiler for measuring micro structures. Can do wafer mapping.
|3D Profiler for measuring micro structures. Can do wafer mapping.
|AFM for measuring nanostructures and surface roughness
|AFM for measuring nanostructures and surface roughness
|Profiler for measuring micro structures.
|-
|-


Line 45: Line 47:
*Stitching: In principel a hole 6" wafer (time consuming)
*Stitching: In principel a hole 6" wafer (time consuming)
|90 µm square
|90 µm square
|Line scan x: 50-50000 µm
|-
|-


Line 55: Line 58:
*94.4µm ->9984µm
*94.4µm ->9984µm
|1 µm (can go up to 5 µm under special settings)
|1 µm (can go up to 5 µm under special settings)
|130 nm
|-
|-
|-style="background:LightGrey; color:black"
|-style="background:LightGrey; color:black"
Line 63: Line 67:
*0.5µm -> 5µm
*0.5µm -> 5µm
|Depending on scan size and number of samples per line and number of lines - accuracy better than 2%
|Depending on scan size and number of samples per line and number of lines - accuracy better than 2%
|
|-
|-


Line 75: Line 80:
*Confocal (depending on objective): 1nm -> 50nm
*Confocal (depending on objective): 1nm -> 50nm
|<1Å - accuracy better than 2%
|<1Å - accuracy better than 2%
|
|-
|-
|-style="background:LightGrey; color:black"
|-style="background:LightGrey; color:black"
Line 83: Line 89:
*Somewhere between 1:1 and 1:12
*Somewhere between 1:1 and 1:12
|~1:1 with standard cantilever.
|~1:1 with standard cantilever.
|
|-
|-


Line 94: Line 101:
*White broadband LED: 550nm
*White broadband LED: 550nm
|<12 nm on standard cantilever
|<12 nm on standard cantilever
|
|-
|-


Line 101: Line 109:
|Can be done
|Can be done
|No stress calculation capability
|No stress calculation capability
|Cannot be done
|Cannot be done
|Cannot be done
|-
|-
Line 111: Line 120:
|Can be done on a line or an area
|Can be done on a line or an area
|Can be done on a selected surface area  
|Can be done on a selected surface area  
|Recommended to use Dektak XTA or Dektak 8.
|-
|-


Line 120: Line 130:
|Up to more than 6"
|Up to more than 6"
|6" or less
|6" or less
|4" or less
|-
|-


Line 133: Line 144:
|
|
*Almost any material that does not leave residual on the stage, please check the responsible group for any non standard materials
*Almost any material that does not leave residual on the stage, please check the responsible group for any non standard materials
|
*Almost any material that does not leave residual on the stage.
|-
|-
|}
|}

Revision as of 11:50, 18 September 2014

Feedback to this page: click here


Topographic measurements are measurements were you can measure hight differences on your substrate. If you measure in many spots of the substrate you can get a topographic image of the substrate.

AT DANCHIP we have four systems for topographic measurement:

  • Dektak (there are two systems) - Profiler for measuring micro structures
  • Optical Profiler (Sensofar) - 3D Profiler for measuring micro structures
  • Nanoman - AFM for measuring nano structures

High Aspect ratio structures
The fact that the tips of the Dektak profilers and the AFM are shaped like a cone with some tip angle causes a problem when characterizing high aspect ratio structures. For instance, if a 20 µm wide trench is etched deeper than approximately 18 µm, the tip of the Dektak will not be able to reach the bottom. The optical profiler uses a light beam that is focused through an objective. Therefore it is able to measure higher aspect ratios. The aspect ratio is limited by the posibility for the light to reach the bottom and get back to the detector. On some samples we have been able to measure aspect ratios above 1:10. Otherwise the solution is to cleave the sample along a line that is perpendicular to the trench and then inspect the profile in a scanning electron microscope or a microscope (for large structures).


Comparison of the two stylus profilers, the optical profiler and the AFM

Dektak 8 stylus profiler Dektak XTA_new stylus profiler Optical Profiler (Sensofar) Nanoman Dektak III-V Profiler
Generel description Profiler for measuring micro structures. Can do wafer mapping and stress measurements. Profiler for measuring micro structures. Can do wafer mapping and stress measurements. 3D Profiler for measuring micro structures. Can do wafer mapping. AFM for measuring nanostructures and surface roughness Profiler for measuring micro structures.
Max. scan range xy Line scan x: 50µm to 200mm Line scan x: 50µm to 55mm in one scan. Maximum scan lenght with stiching 200mm. Depending on the objective:
  • One view: 127µmX95µm to 1270µmX955µm
  • Stitching: In principel a hole 6" wafer (time consuming)
90 µm square Line scan x: 50-50000 µm
Max. scan range z 50Å to 1mm 50Å to 1mm Depending on the objective and Z resolution:
  • 94.4µm ->9984µm
1 µm (can go up to 5 µm under special settings) 130 nm
Resolution xy down to 0.067 µm down to 0.003 µm Depending on the objective:
  • 0.5µm -> 5µm
Depending on scan size and number of samples per line and number of lines - accuracy better than 2%
Resolution z 1Å, 10Å, 40Å or 160Å 1Å, 10Å, 80Å or 160Å Depending on measuring methode:
  • PSI down to 0.01 nm
  • VSI down to 1 nm
  • Confocal (depending on objective): 1nm -> 50nm
<1Å - accuracy better than 2%
Max. scan depth [µm] (as a function of trench width W) 1.2*(W[µm]-5µm) 1.2*(W[µm]-5µm) Depending on material and trench width:
  • Somewhere between 1:1 and 1:12
~1:1 with standard cantilever.
Tip radius 5 µm 45o cone 5 µm 45o cone No tip - using light
  • Blue monochromatic LED: 460nm
  • White broadband LED: 550nm
<12 nm on standard cantilever
Stress measurement Can be done Can be done No stress calculation capability Cannot be done Cannot be done
Surface roughness Can be done on a line scan Can be done on a line scan Can be done on a line or an area Can be done on a selected surface area Recommended to use Dektak XTA or Dektak 8.
Substrate size up to 8" up to 6" Up to more than 6" 6" or less 4" or less
Allowed materials
  • Almost any material that does not leave residual on the stage, please check the responsible group for any non standard materials
  • Almost any material that does not leave residual on the stage, please check the responsible group for any non standard materials
  • Almost any material that does not leave residual on the stage, please check the responsible group for any non standard materials
  • Almost any material that does not leave residual on the stage, please check the responsible group for any non standard materials
  • Almost any material that does not leave residual on the stage.