Specific Process Knowledge/Characterization/Thickness Measurer: Difference between revisions
No edit summary |
|||
Line 5: | Line 5: | ||
==Thickness measurer== | ==Thickness measurer== | ||
[[Image:Thicknessmeasurer2007.jpg|thumb|300x300px|Thickness | [[Image:Thicknessmeasurer2007.jpg|thumb|300x300px|Digital Thickness Measurer. Positioned in cleanroom 4]] | ||
The purpose is to measure the thickness of wafers, depths of larger grooves or height of larger mesas. | The purpose is to measure the thickness of wafers, depths of larger grooves or height of larger mesas. | ||
Doing a KOH etch can it be helpful to insure no over etching by making a thickness measurement doing the etch. | Doing a KOH etch can it be helpful to insure no over etching by making a thickness measurement doing the etch. | ||
'''The user manual, technical information and contact information can be found in LabManager:''' | '''The user manual, technical information and contact information can be found in LabManager:''' | ||
Line 21: | Line 19: | ||
|bgcolor="#98FB98" |'''Quality Control (QC) for the Thickness measurer''' | |bgcolor="#98FB98" |'''Quality Control (QC) for the Thickness measurer''' | ||
|- | |- | ||
| | | | ||
The measured standard thickness is 0.1 mm. The measured result have to be within ± 0.005 mm. The QC is preformed ones a year. | |||
*[http://www.labmanager.danchip.dtu.dk/d4Show.php?id=1831&mach=198 The QC procedure]<br> | *[http://www.labmanager.danchip.dtu.dk/d4Show.php?id=1831&mach=198 The QC procedure]<br> | ||
*[http://www.labmanager.danchip.dtu.dk/view_binary.php?fileId=2062 The newest QC data]<br> | *[http://www.labmanager.danchip.dtu.dk/view_binary.php?fileId=2062 The newest QC data]<br> | ||
|} | |} | ||
==Equipment performance and process related parameters== | ==Equipment performance and process related parameters== | ||
{| border="2" cellspacing="2" cellpadding=" | {| border="2" cellspacing="2" cellpadding="3" | ||
|- | |- | ||
!style="background:silver; color:black;" align="center"| | !style="background:silver; color:black;" align="center"| | ||
Line 71: | Line 69: | ||
|- | |- | ||
|} | |} | ||
Revision as of 14:39, 14 January 2014
THIS PAGE IS UNDER CONSTRUCTION
Feedback to this page: click here
Thickness measurer
The purpose is to measure the thickness of wafers, depths of larger grooves or height of larger mesas.
Doing a KOH etch can it be helpful to insure no over etching by making a thickness measurement doing the etch.
The user manual, technical information and contact information can be found in LabManager:
Quality Control - Recipe Parameters and Limits
Quality Control (QC) for the Thickness measurer |
The measured standard thickness is 0.1 mm. The measured result have to be within ± 0.005 mm. The QC is preformed ones a year. |
Purpose |
Thickness measurer |
|
---|---|---|
Performance |
Thickness resolution |
|
Process parameter range |
Process Temperature |
|
Process pressure |
| |
Substrates |
Batch size |
|
Substrate materials allowed |
|