Specific Process Knowledge/Characterization/KLA-Tencor Surfscan 6420: Difference between revisions

From LabAdviser
Mdyma (talk | contribs)
No edit summary
Mdyma (talk | contribs)
Line 5: Line 5:
== KLA-Tencor Surfscan 6420 ==
== KLA-Tencor Surfscan 6420 ==


Write a short description of the equipment(s).  
[[image:Surfscan_at_FAT.JPG|300x300px|right|thumb|The image is from the cleanroom at the place it was refurbish in California.]]
 
Particles counting of a unpatterned surface. A broad range of particles size from 0.1 µm to greater than 3 µm can be measured on a polished silicon or epitaxial layers. Thin films as e.g. Poly-si, Nitride and thermal Oxide can also be inspected. The system will remove small surface roughness so it not count as a particle.  
 


'''The user manual(s), quality control procedure(s) and results, user APV(s), technical information and contact information can be found in LabManager:'''  
'''The user manual(s), quality control procedure(s) and results, user APV(s), technical information and contact information can be found in LabManager:'''  
<!-- remember to remove the type of documents that are not present -->
<!-- remember to remove the type of documents that are not present -->
[[image:Surfscan_at_FAT.JPG|300x300px|right|thumb|The image is from the cleanroom at the place it was refurbish in California.]]


<!-- give the link to the equipment info page in LabManager: -->
<!-- give the link to the equipment info page in LabManager: -->

Revision as of 09:59, 23 April 2013

THIS PAGE IS UNDER CONSTRUCTION

Feedback to this page: click here

KLA-Tencor Surfscan 6420

The image is from the cleanroom at the place it was refurbish in California.

Particles counting of a unpatterned surface. A broad range of particles size from 0.1 µm to greater than 3 µm can be measured on a polished silicon or epitaxial layers. Thin films as e.g. Poly-si, Nitride and thermal Oxide can also be inspected. The system will remove small surface roughness so it not count as a particle.


The user manual(s), quality control procedure(s) and results, user APV(s), technical information and contact information can be found in LabManager:

LabManager

Equipment performance and process related parameters

Equipment Equipment 1 Equipment 2
Purpose
  • Purpose 1
  • Purpose 2
  • Purpose 1
  • Purpose 2
  • Purpose 3
Performance Response 1
  • Performance range 1
  • Performance range 2
  • Performance range 1
  • Performance range 2
  • Performance range 3
Response 2
  • Performance range
  • Performance range
Process parameter range Parameter 1
  • Range
  • Range
Parameter 2
  • Range
  • Range
Substrates Batch size
  • # small samples
  • # 50 mm wafers
  • # 100 mm wafers
  • # 150 mm wafers
  • # small samples
  • # 50 mm wafers
  • # 100 mm wafers
  • # 150 mm wafers
Allowed materials
  • Allowed material 1
  • Allowed material 2
  • Allowed material 1
  • Allowed material 2
  • Allowed material 3