Specific Process Knowledge/Characterization/Four-Point Probe: Difference between revisions

From LabAdviser
Mdyma (talk | contribs)
Mdyma (talk | contribs)
Line 16: Line 16:
!style="background:silver; color:black;" align="center"|Purpose  
!style="background:silver; color:black;" align="center"|Purpose  
|style="background:LightGrey; color:black"|
|style="background:LightGrey; color:black"|
|style="background:WhiteSmoke; color:black"|  
|style="background:WhiteSmoke; color:black"| Resistance and resistivity measurement


|-
|-
Line 24: Line 24:
Look at the process knowlege
Look at the process knowlege
|-
|-
!style="background:silver; color:black" align="center" valign="center" rowspan="3"|Process parameter range
!style="background:silver; color:black" align="center" valign="center" rowspan="2"|Process parameter range
|style="background:LightGrey; color:black"|Process Temperature
|style="background:LightGrey; color:black"|Process Temperature
|style="background:WhiteSmoke; color:black"|
|style="background:WhiteSmoke; color:black"|
*900-1150 <sup>o</sup>C
*room temperature
|-
|-
|style="background:LightGrey; color:black"|Process pressure
|style="background:LightGrey; color:black"|Process pressure
|style="background:WhiteSmoke; color:black"|
|style="background:WhiteSmoke; color:black"|
*1 atm
*1 atm
|-
|style="background:LightGrey; color:black"|Gasses on the system
|style="background:WhiteSmoke; color:black"|
*Ar, N<sub>2</sub>
|-
|-
!style="background:silver; color:black" align="center" valign="center" rowspan="2"|Substrates
!style="background:silver; color:black" align="center" valign="center" rowspan="2"|Substrates
|style="background:LightGrey; color:black"|Batch size
|style="background:LightGrey; color:black"|Batch size
|style="background:WhiteSmoke; color:black"|
|style="background:WhiteSmoke; color:black"|
*1-30 4" wafer (or 2" wafers) per run
*1 4" wafer per measurement
|-
|-
| style="background:LightGrey; color:black"|Substrate material allowed
| style="background:LightGrey; color:black"|Substrate material allowed
|style="background:WhiteSmoke; color:black"|
|style="background:WhiteSmoke; color:black"|
*Silicon wafers (new from the box or RCA cleaned)
*Silicon wafers (new from the box or RCA cleaned)
*In doubt: look at [http://www.labmanager.danchip.dtu.dk/view_binary.php?fileId=1250 the cross contamination chart] or send a mail to [mailto:furnace@danchip.dtu.dk the Furnace group].
|-  
|-  
|}
|}

Revision as of 11:04, 29 November 2012

Four-Point Probe

The Four-Point Probe is a Veeco FPP-5000 for I/V measurement. The main purpose it to measure resistance and resistivity on a 4" silicon wafer. But can also be used to find thickness of thin layers or test if is a N- or P-type wafer.

The wafer are pushed down on the four pins so a measurement is performed. It works only for 4" wafers because a special holder is need.

Four point probe: positioned in cleanroom 4

The user manual,technical information and contact information can be found in LabManager:

Four point probe

Overview of the performance of the Four-Point Probe and some process related parameters

Purpose Resistance and resistivity measurement
Performance

Look at the process knowlege

Process parameter range Process Temperature
  • room temperature
Process pressure
  • 1 atm
Substrates Batch size
  • 1 4" wafer per measurement
Substrate material allowed
  • Silicon wafers (new from the box or RCA cleaned)