The DREM processes

DREM 2kW micro

DREM 2kW micro
Recipe General Pressure Gases Generators Matching Tem- pera- ture Results
C4F8 SF6 O2 Ar Coil Platen Coil Platen
Platen Stb S/E Dp Et Cyc Dp Et Dp Et Dp Et Dp Et Dp Et Dp Et Dp Et Dp Et Dp Et Runs Keywords
U/D H/L D B M D B M D B M D B M D B M D B M D B M L T L T L T L T
DREM 2kW micro Pump to base, Clamp Substrate, home platen matching unit, stabilisation 8
U HF D/E 1.2 3 100% 100% 0.3@5 0.5@50 200 0.5@100 5 0.3@200 0.5@200 15 2@15 0.3@100 200 150 150 2 2 1 1@1 1@100 1 40 50 40 50 32.5 51.9 32.5 51.9 0
DREM 2kW micro Pump to base, Clamp Substrate, home platen matching unit, stabilisation 1
U HF D/E 1.2 3 100% 100% 0.3@5 0.5@50 200 0.5@100 5 0.3@200 0.5@200 15 2@15 0.3@100 200 150 150 2 2 1 1@1 1@100 1 40 50 40 50 32.5 51.9 32.5 51.9 -19
0 Home matching  
General Time Pressure Gas " >Power Matching Miscellaneous
Setting 90t 7T sulf yes, lots lit na