Jump to content

Specific Process Knowledge/Lithography/Aligners/Aligner: Maskless 01 processing: Difference between revisions

Jehem (talk | contribs)
Jehem (talk | contribs)
Line 44: Line 44:
| 80 mJ/cm<sup>2</sup>
| 80 mJ/cm<sup>2</sup>
| -4
| -4
| 2 µm (due to stitching)
| 2 µm
| Dev: SP60s
| Dev: SP60s
|-style="background:WhiteSmoke; color:black"
|-style="background:WhiteSmoke; color:black"
|
| 2021-08-19<br>jehem
| 1.5 µm
| 1.5 µm
| Quality
| Quality
Line 84: Line 84:
| 300 mJ/cm<sup>2</sup>
| 300 mJ/cm<sup>2</sup>
| 0
| 0
| 2 µm (due to stitching)
| 2 µm (due to stitching)<br>Results poor due to resist dehydration?
| PEB: 60s@110°C, Dev: SP60s
| PEB: 60s@110°C, Dev: SP60s
|-style="background:WhiteSmoke; color:black"
|-style="background:WhiteSmoke; color:black"
Line 92: Line 92:
| 225 mJ/cm<sup>2</sup>  
| 225 mJ/cm<sup>2</sup>  
| -4
| -4
| 1.25 µm
| 1.25 µm<br>Tested using dehydration reducing measures
| PEB: 60s@110°C, Dev: SP60s
| PEB: 60s@110°C, Dev: SP60s
|-
|-
Line 99: Line 99:
|-style="background:WhiteSmoke; color:black"
|-style="background:WhiteSmoke; color:black"
!rowspan="2"| AZ nLOF 2020
!rowspan="2"| AZ nLOF 2020
|
| 2020-02-01<br>jehem
| 2.0 µm
| 2.0 µm
| Fast
| Fast
| 300 mJ/cm<sup>2</sup> (Jehem Feb 2020)
| 300 mJ/cm<sup>2</sup>
| 0 (Jehem Feb 2020)
| 0  
| 2 µm (due to stitching)
| 2 µm (due to stitching)
| PEB: 60s@110°C, Dev: SP60s
| PEB: 60s@110°C, Dev: SP60s
|-style="background:WhiteSmoke; color:black"
|-style="background:WhiteSmoke; color:black"
|
| 2020-03-01<br>taran
| 2.0 µm
| 2.0 µm
| Quality
| Quality
| 180-200 mJ/cm<sup>2</sup> (Taran Mar 2020)
| 180-200 mJ/cm<sup>2</sup>
| 0-1 (Jehem Mar 2020)
| 0
| 1 µm
| 1 µm
| PEB: 60s@110°C, Dev: SP60s
| PEB: 60s@110°C, Dev: SP60s