Jump to content

Specific Process Knowledge/Characterization/Optical microscope: Difference between revisions

Jehem (talk | contribs)
Jehem (talk | contribs)
Line 512: Line 512:
|-
|-
|-style="background:white; color:black; vertical-align:middle; text-align:center;"
|-style="background:white; color:black; vertical-align:middle; text-align:center;"
|
!Nikon SMZ 1000
!Nikon SMZ 1000
!Noco IR
!Noco IR
Line 528: Line 529:
|-
|-
|-style="background:white; color:black; vertical-align:middle; text-align:center;"
|-style="background:white; color:black; vertical-align:middle; text-align:center;"
|
|[[image:Nikon SMZ 1000.jpg|100x100px|thumb|center]]
|[[image:Nikon SMZ 1000.jpg|100x100px|thumb|center]]
|[[image:Noco IR microscope.jpg|100x100px|thumb|center]][[image:Noco IR microscope_1.jpg|100x100px|thumb|center]]
|[[image:Noco IR microscope.jpg|100x100px|thumb|center]][[image:Noco IR microscope_1.jpg|100x100px|thumb|center]]
Line 543: Line 545:


|-
|-
|-style="background:LightGrey; color:black; vertical-align:middle; text-align:center;"
|-style="background:LightGrey; color:black; vertical-align:middle; text-align:left;"
|Location
|346-901
|346-901
|346-901
|C1
|C1
|D3
|D3
|E4
|E5
|F1
|F2
|F3
|-
 
|-
|-style="background:WhiteSmoke; color:black; vertical-align:middle; text-align:left;"
|Responsible group
|Wet chemistry
|Wet chemistry
|Wet chemistry
|Thin Film
|Thin Film
|Thin Film
|Thin Film
|Lithography
|Lithography
|Thin Film
|Thin Film
|Lithography
|-
 
|-
|-style="background:LightGrey; color:black; vertical-align:middle; text-align:left;"
|Objectives
|Zoom 0.8x - 8x
|
*2.5x
*10x
*20x
*50x
|
*2.5x
*5x
*10x
*20x
*50x
|
*2.5x
*5x
*10x
*20x
*50x
*100x
|
*5x
*10x
*20x
*50x
*100x
|
*2.5x
*5x
*10x
*20x
*50x
*100x
|
*2.5x
*5x
*10x
*20x
*50x
|
*2.5x
*5x
*10x
*20x
*50x
*100x
|
*2.5x
*5x
*10x
*20x
*50x
*100x
|
|
*5x
*10x
*20x
*50x
*100x
|Zoom 1x - 8x
|
*5x
*10x
*20x
*50x
|-
|-


|-
|-
|-style="background:WhiteSmoke; color:black; vertical-align:middle; text-align:center;"
|-style="background:WhiteSmoke; color:black; vertical-align:middle; text-align:left;"
|Ocular
|10x
|10x
|10x
|10x
|10x
|10x
|10x
|10x
|10x
|10x
|10x
|10x
|-
 
|-
|-style="background:LightGrey; color:black; vertical-align:middle; text-align:left;"
|Special features
|Stereoscopic microscope
|IR imaging
|
|
|
|
|
*Motorized stage
*'''[[Specific_Process_Knowledge/Characterization/Optical microscope/Nikon Eclipse L200 auto scan guide|Auto scan guide]]'''
|
|
|
|
|Stereoscopic microscope
|
|-
|-
|-style="background:WhiteSmoke; color:black; vertical-align:middle; text-align:left;"
|Features
|
*Episcopic
|
*Polarizer
*Episcopic
*Diascopic
*Brightfield
|
*Episcopic
*Diascopic
*Brightfield
*Darkfield
|
*Episcopic
*Diascopic
*Brightfield
*Darkfield
|
*Polarizer
*Episcopic
*Diascopic
*Brightfield
|
*Episcopic
*Diascopic
*Brightfield
*Darkfield
|
*Episcopic
*Diascopic
*Brightfield
|
*Polarizer
*Episcopic
*Diascopic
*Brightfield
*Darkfield
|
*Polarizer
*Episcopic
*Diascopic
*Brightfield
*Darkfield
|
*Polarizer
*Episcopic
*Brightfield
*Darkfield
|
*Episcopic
|
*Episcopic
*Diascopic
*Brightfield
*Darkfield
|-
|-
|-style="background:LightGrey; color:black; vertical-align:middle; text-align:left;"
|Camera
|None
|IR camera
|DS-Fi2
|DS-Fi1
|None
|DS-Fi1
|DX40-274FW
|
*DS-Fi2
*C-mount, 0.7x relay
|
*DS-Fi2
*C-mount, 0.7x relay
|DS-Fi2
|None
|Infinity X
|-
|-
|-style="background:WhiteSmoke; color:black; vertical-align:middle; text-align:left;"
|Analysis software
|None
|None
|NIS-D
|NIS-D
|None
|NIS-BR
|Kappa Control Center
|NIS-D
|NIS-D
|NIS-D
|None
|DeltaPix
|-
|-