Jump to content

Specific Process Knowledge/Characterization/Sample imaging: Difference between revisions

Jmli (talk | contribs)
Pevo (talk | contribs)
Line 59: Line 59:
[[Specific_Process_Knowledge/Characterization/SEM_Supra_2| SEM Supra 2]],  
[[Specific_Process_Knowledge/Characterization/SEM_Supra_2| SEM Supra 2]],  
[[Specific_Process_Knowledge/Characterization/SEM_Supra_3| SEM Supra 3]],  
[[Specific_Process_Knowledge/Characterization/SEM_Supra_3| SEM Supra 3]],  
[[Specific_Process_Knowledge/Characterization/SEM_LEO| SEM Leo]],
[[Specific_Process_Knowledge/Characterization/SEM_Tabletop_1| SEM Tabletop 1]])
[[Specific_Process_Knowledge/Characterization/SEM_Tabletop_1| SEM Tabletop 1]])


Line 74: Line 73:
|Light
|Light
|
|
Detection of
*Secondary electrons
*Secondary electrons
*Backscattered electrons
*Backscattered electrons
Line 89: Line 89:
*Film thickness
*Film thickness
|
|
*Structure dimensions
*Surface topography
*Material composition
|3D surface topography
|3D surface topography
|3D surface topography (if you make a map scan)
|3D surface topography (if you make a map scan)
Line 103: Line 106:
*PSI: 0.01 nm
*PSI: 0.01 nm
*VSI: 1 nm
*VSI: 1 nm
|1-20 nm
|1-100 nm (lowest resolution for the SEM Tabletop 1)
Depends on what SEM you use
Depends on what SEM you use
|< 1Å  
|< 1Å  
Line 116: Line 119:
*10x objective: 4.95 &mu;m  
*10x objective: 4.95 &mu;m  
*100x objective: 0.495 &mu;m
*100x objective: 0.495 &mu;m
|1-20 nm
|1-100 nm  
Depends on what SEM you use
Depends on what SEM you use
|Down to 1.4 nm
|Down to 1.4 nm
Line 197: Line 200:
|
|
|Samples have to be (semi)conducting, but may have a thin (> ~ 5 µm) layers of non-conducting materials on top.
|Samples have to be (semi)conducting, but may have a thin (> ~ 5 µm) layers of non-conducting materials on top.
Non-conducting samples can be studied using VP (variable pressure) mode in the SEM Suora 1, 2 and 3
|Sample dimensions have to be smaller than stylus dimensions
|Sample dimensions have to be smaller than stylus dimensions
|Sample dimensions have to be smaller than tip dimensions
|Sample dimensions have to be smaller than tip dimensions
Line 221: Line 225:
*One 100 mm wafer  
*One 100 mm wafer  
*One 150 mm wafer  
*One 150 mm wafer  
*One 2000 mm wafer  
:(not possible to inspect entire wafer in SEM Supra 1 and 3)
:(only Supra 2, not possible to inspect entire wafer)
*One 200 mm wafer  
:(only SEM Supra 2, not possible to inspect entire wafer)
|
|
*One small sample
*One small sample
Line 244: Line 249:
|
|
*All sample materials, expect:  
*All sample materials, expect:  
Samples that may disintegrate, produce dust/particles or degas (e.g. wet polymers and powders. Samples with resist or polymer should be properly baked and outgassed before SEM inspection
:Samples that may disintegrate, produce dust/particles or degas (e.g. wet polymers and powders). Samples with resist or polymer should be properly baked and outgassed before SEM inspection
|
|
*All standard cleanroom materials, except samples that might damage or stick to the tip.
*All standard cleanroom materials, except samples that might damage or stick to the tip.