Specific Process Knowledge/Thin film deposition/Deposition of Copper: Difference between revisions
No edit summary |
No edit summary |
||
Line 4: | Line 4: | ||
{| border="1" cellspacing="0" cellpadding="3" | {| border="1" cellspacing="0" cellpadding="3" | ||
! | ! | ||
! E-beam evaporation (Alcatel) | ! E-beam evaporation ([[Specific Process Knowledge/Thin film deposition/Alcatel|Alcatel]]) | ||
! E-beam evaporation (Leybold) | ! E-beam evaporation ([[Specific Process Knowledge/Thin film deposition/Leybold|Leybold]]) | ||
|- | |- | ||
| Batch size | | Batch size |
Revision as of 14:37, 5 February 2009
Copper can be deposited by e-beam evaporation. In the chart below you can compare the different deposition equipment.
E-beam evaporation (Alcatel) | E-beam evaporation (Leybold) | |
---|---|---|
Batch size |
|
|
Pre-clean | RF Ar clean | Ar ion bombartment |
Layer thickness | 10Å to 0.5µm | 10Å to 1500Å |
Deposition rate | 2Å/s to 15Å/s | 1Å/s to 5Å/s |
Studies of Cu deposition processes
Roughness of Cu layers - Roughness of Cu layers deposited with Alcatel