Jump to content

Specific Process Knowledge/Wafer cleaning/RCA: Difference between revisions

BGE (talk | contribs)
BGE (talk | contribs)
Line 4: Line 4:
It consists of two solutions: RCA1 and RCA2 plus diluted HF.
It consists of two solutions: RCA1 and RCA2 plus diluted HF.


The RCA1 contains: H<math>_2</math>O, NH<math>_4</math>OH and H<math>_2</math>O<math>_2</math> (5:1:1). It is used for removed of light organics, particles and metal. <br \>
The RCA1 contains: H<math>_2</math>O, NH<math>_4</math>OH and H<math>_2</math>O<math>_2</math> (5:1:1). It is used for removal of light organics, particles and metal. <br \>
The RCA2 contains: H<math>_2</math>O, HCl and H<math>_2</math>O<math>_2</math> (5:1:1). It is used for removal of heavy metals, alkalies and metal hydroxides.
The RCA2 contains: H<math>_2</math>O, HCl and H<math>_2</math>O<math>_2</math> (5:1:1). It is used for removal of heavy metals, alkalies and metal hydroxides.