Jump to content

Specific Process Knowledge/Wafer cleaning/RCA: Difference between revisions

BGE (talk | contribs)
Fj (talk | contribs)
Line 2: Line 2:


The RCA clean is used for cleaning the wafers before taking them into the furnaces and a few other equipments (check the cross contamination sheet).
The RCA clean is used for cleaning the wafers before taking them into the furnaces and a few other equipments (check the cross contamination sheet).
It consist of two solutions: RCA1 and RCA2 plus diluted HF.
It consists of two solutions: RCA1 and RCA2 plus diluted HF.


The RCA1 contains: H<math>_2</math>O, NH<math>_4</math>OH and H<math>_2</math>O<math>_2</math> (5:1:1). It is used for removed of light organics, particles and metal. <br \>
The RCA1 contains: H<math>_2</math>O, NH<math>_4</math>OH and H<math>_2</math>O<math>_2</math> (5:1:1). It is used for removed of light organics, particles and metal. <br \>