Jump to content

Specific Process Knowledge/Etch/KOH Etch: Difference between revisions

Kabi (talk | contribs)
Kabi (talk | contribs)
Line 189: Line 189:
|style="background:WhiteSmoke; color:black"|
|style="background:WhiteSmoke; color:black"|
*28 wt% mixed in the ratio
*28 wt% mixed in the ratio
KOH:H<sub>2</sub>O - 500 g : 1000 ml
KOH:H<sub>2</sub>O - 500 g : 1000 ml, when using pills
KOH:H<sub>2</sub>O - 1000 ml: 1200 ml, when using premixed 50% KOH solution
|style="background:WhiteSmoke; color:black"|
|style="background:WhiteSmoke; color:black"|
*28 wt% mixed in the ratio
*28 wt% mixed in the ratio
KOH:H<sub>2</sub>O - 500 g : 1000 ml
KOH:H<sub>2</sub>O - 500 g : 1000 ml, when using pills
KOH:H<sub>2</sub>O - 1000 ml: 1200 ml, when using premixed 50% KOH solution
|style="background:WhiteSmoke; color:black"|
|style="background:WhiteSmoke; color:black"|
*28 wt% mixed in the ratio
*28 wt% mixed in the ratio
KOH:H<sub>2</sub>O - 500 g : 1000 ml
KOH:H<sub>2</sub>O - 500 g : 1000 ml, when using pills
KOH:H<sub>2</sub>O - 1000 ml: 1200 ml, when using premixed 50% KOH solution
|style="background:WhiteSmoke; color:black"|
|style="background:WhiteSmoke; color:black"|
*Custom made
*Custom made