Specific Process Knowledge/Wafer and sample drying: Difference between revisions

From LabAdviser
Kabi (talk | contribs)
Kabi (talk | contribs)
Line 5: Line 5:
{| border="2" cellspacing="0" cellpadding="2"  
{| border="2" cellspacing="0" cellpadding="2"  


!colspan="1" border="none" style="background:silver; color:black;" align="center"|Equipment  
|-style="background:lightgray; color:black"
|style="background:WhiteSmoke; color:black"|<b>Spin dryer 1</b>
!Equipment  
|style="background:WhiteSmoke; color:black"|<b>Spin dryer 2</b>
![[Specific_Process_Knowledge/Lithography/Baking#Hotplate:_90-110C|Hotplate: 90-110C]]
|style="background:WhiteSmoke; color:black"|<b>Spin dryer 3</b>
|<b>Spin dryer 1</b>
|style="background:WhiteSmoke; color:black"|<b>Spin dryer 4</b>
|<b>Spin dryer 2</b>
|style="background:WhiteSmoke; color:black"|<b>Single Wafer Spin dryer 1</b>
|<b>Spin dryer 3</b>
|style="background:WhiteSmoke; color:black"|<b>Single Wafer Spin dryer 2</b>
|<b>Spin dryer 4</b>
|style="background:WhiteSmoke; color:black"|<b>Single Wafer Spin dryer 3</b>
|<b>Single Wafer Spin dryer 1</b>
|style="background:WhiteSmoke; color:black"|<b>Critical point dryer</b>
|<b>Single Wafer Spin dryer 2</b>
|style="background:WhiteSmoke; color:black"|<b>Ethanol fume dryer</b>
|<b>Single Wafer Spin dryer 3</b>
|style="background:WhiteSmoke; color:black"|<b>N<sub>2</sub> guns</b>
|<b>Critical point dryer</b>
|<b>Ethanol fume dryer</b>
|<b>N<sub>2</sub> guns</b>
|-
|-
!style="background:silver; color:black;" align="center" width="60"|Location
 
|style="background:WhiteSmoke; color:black"|
|-style="background:WhiteSmoke; color:black"
!Location
|
*C-1
*C-1
|style="background:WhiteSmoke; color:black"|
|
*B-1
*B-1
|style="background:WhiteSmoke; color:black"|
|
*D-3
*D-3
|style="background:WhiteSmoke; color:black"|
|
*E-5
*E-5
|style="background:WhiteSmoke; color:black"|
|
*B-1
*B-1
|style="background:WhiteSmoke; color:black"|
|
*C-1
*C-1
|style="background:WhiteSmoke; color:black"|
|
*D-3
*D-3
|style="background:WhiteSmoke; color:black"|
|
*D-3
*D-3
|style="background:WhiteSmoke; color:black"|
|
*C-1
*C-1
|style="background:WhiteSmoke; color:black"|
|
*In fumehoods and at chemical benches
*In fumehoods and at chemical benches
|-
|-
!style="background:silver; color:black;" align="center" width="60"|Purpose  
 
|style="background:WhiteSmoke; color:black"|
|-style="background:lightgray; color:black"
!Purpose  
|
*Drying
*Drying
|style="background:WhiteSmoke; color:black"|
|
*Drying   
*Drying   
|style="background:WhiteSmoke; color:black"|
|
*Drying
*Drying
|style="background:WhiteSmoke; color:black"|
|
*Drying
*Drying
*Rinsing + drying
*Rinsing + drying
|style="background:WhiteSmoke; color:black"|
|
*Drying
*Drying
|style="background:WhiteSmoke; color:black"|
|
*Drying
*Drying
|style="background:WhiteSmoke; color:black"|
|
*Drying
*Drying
|style="background:WhiteSmoke; color:black"|
|
*Drying sensitive samples. E.g. with cantilevers
*Drying sensitive samples. E.g. with cantilevers
|style="background:WhiteSmoke; color:black"|
|
*Drying sensitive samples. E.g. with cantilevers
*Drying sensitive samples. E.g. with cantilevers
|style="background:WhiteSmoke; color:black"|
|
*Drying all kind of samples.
*Drying all kind of samples.
|-
|-
!style="background:silver; color:black;" align="center" width="60"|Batch size
 
|style="background:WhiteSmoke; color:black"|
|-style="background:WhiteSmoke; color:black"
!Batch size
|
*1-25 100 mm wafers
*1-25 100 mm wafers
|style="background:WhiteSmoke; color:black"|
|*1-25 100 mm wafers
*1-25 100 mm wafers
|
|style="background:WhiteSmoke; color:black"|
*1-25 100 mm wafers
*1-25 100 mm wafers
*1-25 150 mm wafers
*1-25 150 mm wafers
|style="background:WhiteSmoke; color:black"|
|
*1-25 50 mm wafers
*1-25 50 mm wafers
*1-25 100 mm wafers
*1-25 100 mm wafers
*1-25 150 mm wafers
*1-25 150 mm wafers
|style="background:WhiteSmoke; color:black"|
|
*one 100 mm wafer
*one 100 mm wafer
|style="background:WhiteSmoke; color:black"|
|
*one 100 mm wafer
*one 100 mm wafer
|style="background:WhiteSmoke; color:black"|
|
*one 100 mm wafer  
*one 100 mm wafer  
|style="background:WhiteSmoke; color:black"|
|
*1 to 5 wafers per run. Sizes: 2”, 4" or 6"
*1 to 5 wafers per run. Sizes: 2”, 4" or 6"
* Pieces (up to 10x10mm)
* Pieces (up to 10x10mm)
|style="background:WhiteSmoke; color:black"|
|
*1-25 50 mm wafers
*1-25 50 mm wafers
*1-25 100 mm wafers
*1-25 100 mm wafers
*Pieces if a suitable carrier is available
*Pieces if a suitable carrier is available
|style="background:WhiteSmoke; color:black"|
|
*One sample at a time
*One sample at a time
|-
|-
!style="background:silver; color:black;" align="center" width="60"|Allowed materials
 
|style="background:WhiteSmoke; color:black"|
|-style="background:lightgray; color:black"
!Allowed materials
|
*No restrictions
*No restrictions
|style="background:WhiteSmoke; color:black"|
|
*Only for RCA cleaned wafers
*Only for RCA cleaned wafers
|style="background:WhiteSmoke; color:black"|
|
*No restrictions
*No restrictions
|style="background:WhiteSmoke; color:black"|
|
*No restrictions
*No restrictions
|style="background:WhiteSmoke; color:black"|
|
*No restrictions
*No restrictions
|style="background:WhiteSmoke; color:black"|
|
*No restrictions
*No restrictions
|style="background:WhiteSmoke; color:black"|
|
*No restrictions
*No restrictions
|style="background:WhiteSmoke; color:black"|
|
*Si,SiO2, Si3N4
*Si,SiO2, Si3N4
*Quartz and Pyrex
*Quartz and Pyrex
*InAlP, GaAs
*InAlP, GaAs
*SU8
*SU8
|style="background:WhiteSmoke; color:black"|
|
*No restriction except for polymers
*No restriction except for polymers
|style="background:WhiteSmoke; color:black"|
|
*No restriction
*No restriction
|-  
|-  

Revision as of 11:30, 14 November 2014

Feedback to this page: click here

Drying Comparison Table

Equipment Hotplate: 90-110C Spin dryer 1 Spin dryer 2 Spin dryer 3 Spin dryer 4 Single Wafer Spin dryer 1 Single Wafer Spin dryer 2 Single Wafer Spin dryer 3 Critical point dryer Ethanol fume dryer N2 guns
Location
  • C-1
  • B-1
  • D-3
  • E-5
  • B-1
  • C-1
  • D-3
  • D-3
  • C-1
  • In fumehoods and at chemical benches
Purpose
  • Drying
  • Drying
  • Drying
  • Drying
  • Rinsing + drying
  • Drying
  • Drying
  • Drying
  • Drying sensitive samples. E.g. with cantilevers
  • Drying sensitive samples. E.g. with cantilevers
  • Drying all kind of samples.
Batch size
  • 1-25 100 mm wafers
*1-25 100 mm wafers
  • 1-25 100 mm wafers
  • 1-25 150 mm wafers
  • 1-25 50 mm wafers
  • 1-25 100 mm wafers
  • 1-25 150 mm wafers
  • one 100 mm wafer
  • one 100 mm wafer
  • one 100 mm wafer
  • 1 to 5 wafers per run. Sizes: 2”, 4" or 6"
  • Pieces (up to 10x10mm)
  • 1-25 50 mm wafers
  • 1-25 100 mm wafers
  • Pieces if a suitable carrier is available
  • One sample at a time
Allowed materials
  • No restrictions
  • Only for RCA cleaned wafers
  • No restrictions
  • No restrictions
  • No restrictions
  • No restrictions
  • No restrictions
  • Si,SiO2, Si3N4
  • Quartz and Pyrex
  • InAlP, GaAs
  • SU8
  • No restriction except for polymers
  • No restriction


Choose a drying equipment