LabAdviser/314/Microscopy 314-307/TEM/Sample Holders: Difference between revisions

From LabAdviser
Bghe (talk | contribs)
Created page with "=<span style="background:#FF2800">THIS PAGE IS UNDER CONSTRUCTION</span>200px= '''Feedback to this page''': '''[mailto:labadviser@danchip.dtu..."
 
Jenk (talk | contribs)
No edit summary
 
(24 intermediate revisions by the same user not shown)
Line 1: Line 1:
<!-- <span style="background:#FF2800">THIS PAGE IS UNDER CONSTRUCTION</span>[[image:Under_construction.png|200px]] -->
'''Feedback to this page''': '''[mailto:labadviser@nanolab.dtu.dk?Subject=Feed%20back%20from%20page%20http://labadviser.nanolab.dtu.dk/index.php/LabAdviser/314/Microscopy_314-307/TEM/Sample_Holders click here]'''
''This section is written by DTU Nanolab internal if nothing else is stated.''
[[Category:314]]
[[Category:314-Microscopy]]
=<span style="background:#FF2800">THIS PAGE IS UNDER CONSTRUCTION</span>[[image:Under_construction.png|200px]]=
=<span style="background:#FF2800">THIS PAGE IS UNDER CONSTRUCTION</span>[[image:Under_construction.png|200px]]=


'''Feedback to this page''': '''[mailto:labadviser@danchip.dtu.dk?Subject=Feed%20back%20from%20page%20http://labadviser.danchip.dtu.dk/index.php?title=LabAdviser/CEN/Sample_Holders click here]'''
= Holders for general imaging =
<!-- Replace "http://labadviser.danchip.dtu.dk/..." with the link to the Labadviser page-->
 
== Fischione 2020 tomography holder ==
 
== FEI single tilt holder ==
 
Standard sample holder available for the Tecnai microscopes and the ATEM.
 
== FEI double tilt ==
 
The holder has a beta-tilt of about +/-30&deg;. The specimen cradle and clamping material (hexring and anti-twist washer) are made of beryllium to minimize unwanted X-ray signal from the holder.
 
== Gatan double tilt beryllium holder ==
 
The holder has a beta-tilt of about +/-30&deg;. The specimen cradle and clamping material (hexring and anti-twist washer) are made of beryllium to minimize unwanted X-ray signal from the holder. The holder has a Faraday-cup at the tip for possible measurement of the beam current (with an external picoampermeter).
<br>
 
 
= Holders for EDS analyses =
 
== Gatan double tilt beryllium holder ==
 
The holder has a beta-tilt of about +/-30&deg;. The specimen cradle and clamping material (hexring and anti-twist washer) are made of beryllium to minimize unwanted X-ray signal from the holder. The holder has a Faraday-cup at the tip for possible measurement of the beam current (with an external picoampermeter).
 
== FEI double tilt ==
 
The holder has a beta-tilt of about +/-30&deg;. The specimen cradle and clamping material (hexring and anti-twist washer) are made of beryllium to minimize unwanted X-ray signal from the holder.
<br>
 
 
= Holders for heating experiments =
 
== DENSsolution Wildfire single tilt heating holder ==
 
MEMS-based holder for heating up to 1300&deg;C. It is a single tilt holder which is also suitable for EDS.
<br>
 
== Protochips Fusion Select double tilt heating holder ==
 
This MEMS-based holder has 6 contacts, which allows for heating, electrical biasing/measuring and the combination of both. It has beta-tilt capabilities up to about +/- 20&deg; and is suitable for EDS. The chips can be heated up to about 1200&deg;C.
<br>
 
== Gatan 652 In double tilt heating holder ==
 
Classical furnace heating holder which is suited for standard 3mm samples. The heating furnace is made from Inconel and suited for heating in oxidizing gas environments (ETEM) up to about 800&deg;C. This holder is not suited for EDS because of the furnace design.
<br>
 
== Gatan 652 Ta double tilt heating holder ==
 
Classical furnace heating holder which is suited for standard 3mm samples. The heating furnace is made from tantalum and ONLY suited for heating in non-oxidizing gas environments (ETEM) up to about 1000&deg;C. This holder is not suited for EDS because of the furnace design.
<br>
<br>
 
= Holders for cryo experiments =
 
== Gatan single tilt cryo holder ==


= Fischione 2020 tomography holder =
== Gatan double tilt liquid nitrogen cold holder ==


= DensSolution Single tilt heating holder =
== He cooling holder ==
<br>


= Protochips Aduro single tilt heating holder =
= Holders for tomography =


= Gatan 652 In double tilt heating holder =
== Fischione 2020 tomography holder ==


= Gatan 652 Ta double tilt heating holder =
== Fischione 2040 dual axis tomography holder ==


= FEI double tilt =
== Fischione 2070 vacuum transfer tomography holder ==
<br>


= Fischione dual axis tomography holder =
= Special Holders =


= Gatan single tilt cryo holder =
== DENSsolution Climate gas and heating holder ==


= Gatan double tilt beryllium holder =
The MEMS-based closed-cell holder offers the possibility of gas environments up to atmospheric pressure (1bar). Up to three gasses can be used simultaneously. Additionally, it offers temperature control up to 1000&deg;C. The setup is also equipped with an residual gas analyzer to detect reaction products.


= Gatan double tilt liquid nitrogen cold holder =
<br>


= Gatan double-tilt beryllium holder =
== Fischione two-contact biasing holder ==
<br>

Latest revision as of 09:20, 27 June 2023

Feedback to this page: click here

This section is written by DTU Nanolab internal if nothing else is stated.

THIS PAGE IS UNDER CONSTRUCTION

Holders for general imaging

Fischione 2020 tomography holder

FEI single tilt holder

Standard sample holder available for the Tecnai microscopes and the ATEM.

FEI double tilt

The holder has a beta-tilt of about +/-30°. The specimen cradle and clamping material (hexring and anti-twist washer) are made of beryllium to minimize unwanted X-ray signal from the holder.

Gatan double tilt beryllium holder

The holder has a beta-tilt of about +/-30°. The specimen cradle and clamping material (hexring and anti-twist washer) are made of beryllium to minimize unwanted X-ray signal from the holder. The holder has a Faraday-cup at the tip for possible measurement of the beam current (with an external picoampermeter).


Holders for EDS analyses

Gatan double tilt beryllium holder

The holder has a beta-tilt of about +/-30°. The specimen cradle and clamping material (hexring and anti-twist washer) are made of beryllium to minimize unwanted X-ray signal from the holder. The holder has a Faraday-cup at the tip for possible measurement of the beam current (with an external picoampermeter).

FEI double tilt

The holder has a beta-tilt of about +/-30°. The specimen cradle and clamping material (hexring and anti-twist washer) are made of beryllium to minimize unwanted X-ray signal from the holder.


Holders for heating experiments

DENSsolution Wildfire single tilt heating holder

MEMS-based holder for heating up to 1300°C. It is a single tilt holder which is also suitable for EDS.

Protochips Fusion Select double tilt heating holder

This MEMS-based holder has 6 contacts, which allows for heating, electrical biasing/measuring and the combination of both. It has beta-tilt capabilities up to about +/- 20° and is suitable for EDS. The chips can be heated up to about 1200°C.

Gatan 652 In double tilt heating holder

Classical furnace heating holder which is suited for standard 3mm samples. The heating furnace is made from Inconel and suited for heating in oxidizing gas environments (ETEM) up to about 800°C. This holder is not suited for EDS because of the furnace design.

Gatan 652 Ta double tilt heating holder

Classical furnace heating holder which is suited for standard 3mm samples. The heating furnace is made from tantalum and ONLY suited for heating in non-oxidizing gas environments (ETEM) up to about 1000°C. This holder is not suited for EDS because of the furnace design.

Holders for cryo experiments

Gatan single tilt cryo holder

Gatan double tilt liquid nitrogen cold holder

He cooling holder


Holders for tomography

Fischione 2020 tomography holder

Fischione 2040 dual axis tomography holder

Fischione 2070 vacuum transfer tomography holder


Special Holders

DENSsolution Climate gas and heating holder

The MEMS-based closed-cell holder offers the possibility of gas environments up to atmospheric pressure (1bar). Up to three gasses can be used simultaneously. Additionally, it offers temperature control up to 1000°C. The setup is also equipped with an residual gas analyzer to detect reaction products.


Fischione two-contact biasing holder