=<span style="background:#FF2800">THIS PAGE IS UNDER CONSTRUCTION</span>[[image:Under_construction.png|200px]]=
=<span style="background:#FF2800">THIS PAGE IS UNDER CONSTRUCTION</span>[[image:Under_construction.png|200px]]=
Line 12: Line 9:


== FEI single tilt holder ==
== FEI single tilt holder ==
Standard sample holder available for the Tecnai microscopes and the ATEM.


== FEI double tilt ==
== FEI double tilt ==
The holder has a beta-tilt of about +/-30&deg;. The specimen cradle and clamping material (hexring and anti-twist washer) are made of beryllium to minimize unwanted X-ray signal from the holder.


== Gatan double tilt beryllium holder ==
== Gatan double tilt beryllium holder ==
The holder has a beta-tilt of about +/-30&deg;. The specimen cradle and clamping material (hexring and anti-twist washer) are made of beryllium to minimize unwanted X-ray signal from the holder. The holder has a Faraday-cup at the tip for possible measurement of the beam current (with an external picoampermeter).
<br>
<br>


= Holders for EDS analyses =
= Holders for EDS analyses =


== Gatan double tilt beryllium holder ==
== Gatan double tilt beryllium holder ==
The holder has a beta-tilt of about +/-30&deg;. The specimen cradle and clamping material (hexring and anti-twist washer) are made of beryllium to minimize unwanted X-ray signal from the holder. The holder has a Faraday-cup at the tip for possible measurement of the beam current (with an external picoampermeter).


== FEI double tilt ==
== FEI double tilt ==
The holder has a beta-tilt of about +/-30&deg;. The specimen cradle and clamping material (hexring and anti-twist washer) are made of beryllium to minimize unwanted X-ray signal from the holder.
<br>
<br>


= Holders for heating experiments =
= Holders for heating experiments =


== DensSolution Wildfire single tilt heating holder ==
== DENSsolution Wildfire single tilt heating holder ==


MEMS-based holder for heating up to 1300&deg;C. It is a single tilt holder which is also suitable for EDS.
MEMS-based holder for heating up to 1300&deg;C. It is a single tilt holder which is also suitable for EDS.
Line 45: Line 54:


Classical furnace heating holder which is suited for standard 3mm samples. The heating furnace is made from tantalum and ONLY suited for heating in non-oxidizing gas environments (ETEM) up to about 1000&deg;C. This holder is not suited for EDS because of the furnace design.
Classical furnace heating holder which is suited for standard 3mm samples. The heating furnace is made from tantalum and ONLY suited for heating in non-oxidizing gas environments (ETEM) up to about 1000&deg;C. This holder is not suited for EDS because of the furnace design.
<br>
<br>
<br>


Line 67: Line 77:
= Special Holders =
= Special Holders =


== DensSolution Climate gas and heating holder ==
== DENSsolution Climate gas and heating holder ==
 
The MEMS-based closed-cell holder offers the possibility of gas environments up to atmospheric pressure (1bar). Up to three gasses can be used simultaneously. Additionally, it offers temperature control up to 1000&deg;C. The setup is also equipped with an residual gas analyzer to detect reaction products.
 
<br>


== Fischione two-contact biasing holder ==
== Fischione two-contact biasing holder ==
<br>
<br>