Jump to content

Specific Process Knowledge/Characterization/Optical characterization: Difference between revisions

Bghe (talk | contribs)
No edit summary
Bghe (talk | contribs)
 
(8 intermediate revisions by the same user not shown)
Line 8: Line 8:
For comparison of the methods for measuring optical constants and film thickness, see here: [[Specific Process Knowledge/Characterization/Measurement of film thickness and optical constants#Film_thickness_and_optical_constants_of_optical_transparent_films|Film thickness and optical constants of optical transparent films]]
For comparison of the methods for measuring optical constants and film thickness, see here: [[Specific Process Knowledge/Characterization/Measurement of film thickness and optical constants#Film_thickness_and_optical_constants_of_optical_transparent_films|Film thickness and optical constants of optical transparent films]]


==Ellipsometer VASE and Ellipsometer M-2000V ==
==Ellipsometer RC2, Ellipsometer M2000XI (VASE) and Ellipsometer M-2000V ==
''This section is written by Berit Herstrøm @ DTU Nanolab''
''This section is written by Berit Herstrøm @ DTU Nanolab''
[[image:RC2 system.jpg|275x275px|right|thumb|Ellipsometer RC2: positioned in cleanroom A-1, {{photo1}}]]
[[image:Ellipsometer_VASE_image.JPG|275x275px|right|thumb|Ellipsometer VASE: positioned in cleanroom C-1, {{photo1}}]]
[[image:Ellipsometer_VASE_image.JPG|275x275px|right|thumb|Ellipsometer VASE: positioned in cleanroom C-1, {{photo1}}]]


The ellipsometer VASE is actually a M2000XI-210 ellipsometer from J.A. Woollam Co., Inc.. We call it VASE (Variable Angle Spectroscopic Ellipsometry) because it can do spectroscopic ellipsometry at variable angles. <br/>
The ellipsometer RC2 from J.A. Woollam Co., Inc is the newest of our ellipsometers. It performs slightly better then the M2000 and can measure the full Müller matrix. For most users the differences are very small.  The ellipsometer VASE is actually a M2000XI-210 ellipsometer from J.A. Woollam Co., Inc.. We call it VASE (Variable Angle Spectroscopic Ellipsometry) because it can do spectroscopic ellipsometry at variable angles. <br/>
The ellipsometer M2000V is an in-situ ellipsometer from J.A. Wollam Co., Inc. This dedicated for being used on the Sputter System Lesker instrument or the ALD2 for in-situ measurements. When it is not on any system it is positioned next to the ALD2.
The ellipsometer M2000V is an in-situ ellipsometer from J.A. Wollam Co., Inc. This dedicated for being used on the Sputter System Lesker instrument or the ALD2 for in-situ measurements. When it is not on any system it is positioned next to the ALD2.


Line 29: Line 30:


<!-- give the link to the equipment info page in LabManager: -->
<!-- give the link to the equipment info page in LabManager: -->
[http://labmanager.dtu.dk/function.php?module=Machine&view=view&mach=542 LabManager page for Ellipsometer RC2] <br/>
[http://labmanager.dtu.dk/function.php?module=Machine&view=view&mach=316 LabManager page for Ellipsometer VASE] <br/>
[http://labmanager.dtu.dk/function.php?module=Machine&view=view&mach=316 LabManager page for Ellipsometer VASE] <br/>
[http://labmanager.dtu.dk/function.php?module=Machine&view=view&mach=261 LabManager page for Ellipsometer M-2000V]
[http://labmanager.dtu.dk/function.php?module=Machine&view=view&mach=261 LabManager page for Ellipsometer M-2000V]
Line 45: Line 47:


!colspan="2" border="none" style="background:silver; color:black;" align="center"|Equipment  
!colspan="2" border="none" style="background:silver; color:black;" align="center"|Equipment  
|style="background:WhiteSmoke; color:black"|<b>Ellipsometer RC2</b>
|style="background:WhiteSmoke; color:black"|<b>Ellipsometer VASE (M2000XI)</b>
|style="background:WhiteSmoke; color:black"|<b>Ellipsometer VASE (M2000XI)</b>
|style="background:WhiteSmoke; color:black"|<b>Ellipsometer M-2000V</b>
|style="background:WhiteSmoke; color:black"|<b>Ellipsometer M-2000V</b>
Line 50: Line 53:
!style="background:silver; color:black;" align="center" width="60"|Purpose  
!style="background:silver; color:black;" align="center" width="60"|Purpose  
|style="background:LightGrey; color:black"|  
|style="background:LightGrey; color:black"|  
|style="background:WhiteSmoke; color:black"|
*Measure thinfilm thicknesses and optical constants for single and multilayer optical transparent thinfilms.
*Measure opticals constants for bulk material.
*Measure thinfilm thicknesses and optical constants at elevated temperature <300C
|style="background:WhiteSmoke; color:black"|
|style="background:WhiteSmoke; color:black"|
*Measure thinfilm thicknesses and optical constants for single and multilayer optical transparent thinfilms.
*Measure thinfilm thicknesses and optical constants for single and multilayer optical transparent thinfilms.
Line 59: Line 66:
!style="background:silver; color:black" align="center" valign="center" rowspan="2"|Performance
!style="background:silver; color:black" align="center" valign="center" rowspan="2"|Performance
|style="background:LightGrey; color:black"|Films that can be examined
|style="background:LightGrey; color:black"|Films that can be examined
|style="background:WhiteSmoke; color:black"|
Any film that is transparent to the light in the given wavelength range
e.g.:
*Silicon Oxide
*Silicon nitride
*PolySilicon
*Resists
*Polymers
*Very thin layers of metals
|style="background:WhiteSmoke; color:black"|
|style="background:WhiteSmoke; color:black"|
Any film that is transparent to the light in the given wavelength range
Any film that is transparent to the light in the given wavelength range
Line 82: Line 98:
|style="background:LightGrey; color:black"|Film thickness range
|style="background:LightGrey; color:black"|Film thickness range
|style="background:WhiteSmoke; color:black"|
|style="background:WhiteSmoke; color:black"|
*~20Å to 2 µm (depending of the material)
*~20Å to a few micrometers (depending of the material)
|style="background:WhiteSmoke; color:black"|
|style="background:WhiteSmoke; color:black"|
*~20Å to 2 µm (depending of the material)
*~20Å to a few micrometers (depending of the material)
|style="background:WhiteSmoke; color:black"|
*~20Å to a few micrometer (depending of the material)
|-
|-
!style="background:silver; color:black" align="center" valign="center" rowspan="4"|Process parameter range
!style="background:silver; color:black" align="center" valign="center" rowspan="4"|Process parameter range
|style="background:LightGrey; color:black"|Wavelength range
|style="background:LightGrey; color:black"|Wavelength range
|style="background:WhiteSmoke; color:black"|
*210nm-1690nm
|style="background:WhiteSmoke; color:black"|
|style="background:WhiteSmoke; color:black"|
*210nm-1690nm
*210nm-1690nm
Line 94: Line 114:
|-
|-
|style="background:LightGrey; color:black"|Incident angle range
|style="background:LightGrey; color:black"|Incident angle range
|style="background:WhiteSmoke; color:black"|
*45-90 degrees
|style="background:WhiteSmoke; color:black"|
|style="background:WhiteSmoke; color:black"|
*45-90 degrees
*45-90 degrees
Line 100: Line 122:
|-
|-
|style="background:LightGrey; color:black"|Beam size
|style="background:LightGrey; color:black"|Beam size
|style="background:WhiteSmoke; color:black"|
*3mm (spot size on sample depends on the angle)
|style="background:WhiteSmoke; color:black"|
|style="background:WhiteSmoke; color:black"|
*2mm (spot size on sample depends on the angle)
*2mm (spot size on sample depends on the angle)
Line 107: Line 131:
|style="background:LightGrey; color:black"|Mapping facility
|style="background:LightGrey; color:black"|Mapping facility
|style="background:WhiteSmoke; color:black"|
|style="background:WhiteSmoke; color:black"|
*Can make wafermaps on up to 150mm wafers
*Can make wafer maps on up to 150mm wafers
|style="background:WhiteSmoke; color:black"|
*Can make wafer maps on up to 150mm wafers
|style="background:WhiteSmoke; color:black"|
|style="background:WhiteSmoke; color:black"|
*No mapping facility
*No mapping facility
|-
|-
!style="background:silver; color:black" align="center" valign="center" rowspan="2"|Accessories
!style="background:silver; color:black" align="center" valign="center" rowspan="3"|Accessories
|style="background:LightGrey; color:black"|Focusing optics
|style="background:LightGrey; color:black"|Focusing optics
|style="background:WhiteSmoke; color:black"|
*Focus lenses can be applied, reduces the beam diameter to 120µm
|style="background:WhiteSmoke; color:black"|
|style="background:WhiteSmoke; color:black"|
*Focus lenses can be applied, reduces the beam diameter to 125µm
*Focus lenses can be applied, reduces the beam diameter to 125µm
Line 122: Line 150:
*Extra stage for transmission measurements
*Extra stage for transmission measurements
|style="background:WhiteSmoke; color:black"|
|style="background:WhiteSmoke; color:black"|
*Base for ex-situ measurements, transmission data can be done by holding the sample up agains the detector
*Extra stage for transmission measurements
|style="background:WhiteSmoke; color:black"|
*Base for ex-situ measurements, transmission data can be done by holding the sample up against the detector
|-
|style="background:LightGrey; color:black"|Heating stage
|style="background:WhiteSmoke; color:black"|
*Heating stage for measurements at temperatures up to 300C
|style="background:WhiteSmoke; color:black"|
*None
|style="background:WhiteSmoke; color:black"|
*None
|-
|-
!style="background:silver; color:black" align="center" valign="center" rowspan="2"|Substrates
!style="background:silver; color:black" align="center" valign="center" rowspan="2"|Substrates
|style="background:LightGrey; color:black"|Batch size
|style="background:LightGrey; color:black"|Batch size
|style="background:WhiteSmoke; color:black"|
*One sample at a time smaller than 150mm (ask if you have anything larger)
|style="background:WhiteSmoke; color:black"|
|style="background:WhiteSmoke; color:black"|
*One sample at a time smaller than 150mm (ask if you have anything larger)
*One sample at a time smaller than 150mm (ask if you have anything larger)
Line 135: Line 175:
*Any material that does not leave residuals on the stage and that does not evaporate
*Any material that does not leave residuals on the stage and that does not evaporate
|style="background:WhiteSmoke; color:black"|
|style="background:WhiteSmoke; color:black"|
*Any material that may go into the Sputter system Lesker
*Any material that does not leave residuals on the stage and that does not evaporate
|style="background:WhiteSmoke; color:black"|
*Any material that may go into the ALD2 (when mounted on that system)
|-  
|-  
|}
|}
Line 144: Line 186:
==Filmtek 4000==
==Filmtek 4000==
{{CC-bghe2}}
{{CC-bghe2}}
[[image:Filmtek.JPG|275x275px|right|thumb|FilmTek 4000: positioned in cleanroom A-1, {{photo1}}]]
[[image:Filmtek.JPG|275x275px|right|thumb|FilmTek 4000: positioned in cleanroom D-1, {{photo1}}]]
FilmTek 4000 is a computerized film thickness measurement and material characterization system. This system combines fiber-optic spectrophotometry with advanced material modeling software to provide an affordable and reliable tool for the simultaneous measurement of film thickness, index of refraction, and extinction coefficient
FilmTek 4000 is a computerized film thickness measurement and material characterization system. This system combines fiber-optic spectrophotometry with advanced material modeling software to provide an affordable and reliable tool for the simultaneous measurement of film thickness, index of refraction, and extinction coefficient