Specific Process Knowledge/Characterization: Difference between revisions
Appearance
mNo edit summary |
|||
| (22 intermediate revisions by the same user not shown) | |||
| Line 6: | Line 6: | ||
{| {{table } } | {| {{table } } | ||
| width="30 | | width="30" align="center" style="writing-mode: vertical-lr; transform: rotate(180deg);background:#f0f0f0;"| | ||
| width="30" align="center" style="writing-mode: vertical-lr; transform: rotate(180deg);background:#f0f0f0;"|[[Specific_Process_Knowledge/Characterization/Optical_microscope| Optical Microscopes]] | | width="30" align="center" style="writing-mode: vertical-lr; transform: rotate(180deg);background:#f0f0f0;"|[[Specific_Process_Knowledge/Characterization/Optical_microscope| Optical Microscopes]] | ||
| width="30" align="center" style="writing-mode: vertical-lr; transform: rotate(180deg);background:#f0f0f0;"|[[Specific Process Knowledge/Characterization/SEM: Scanning Electron Microscopy|SEM (incl. EDX)]] | | width="30" align="center" style="writing-mode: vertical-lr; transform: rotate(180deg);background:#f0f0f0;"|[[Specific Process Knowledge/Characterization/SEM: Scanning Electron Microscopy|SEM (incl. EDX)]] | ||
| width="30" align="center" style="writing-mode: vertical-lr; transform: rotate(180deg);background:#f0f0f0;"|[[Specific Process Knowledge/Characterization/AFM: Atomic Force Microscopy|AFM]] | | width="30" align="center" style="writing-mode: vertical-lr; transform: rotate(180deg);background:#f0f0f0;"|[[Specific Process Knowledge/Characterization/AFM: Atomic Force Microscopy|AFM]] | ||
| width="30" align="center" style="writing-mode: vertical-lr; transform: rotate(180deg);background:#f0f0f0;"|[[Specific Process Knowledge/Characterization/ | | width="30" align="center" style="writing-mode: vertical-lr; transform: rotate(180deg);background:#f0f0f0;"|[[Specific Process Knowledge/Characterization/Topographic measurement#Comparison of Stylus Profilers, Optical Profilers and AFMs at Nanolab|Stylus profilers]] | ||
| width="30" align="center" style="writing-mode: vertical-lr; transform: rotate(180deg);background:#f0f0f0;"|[[Specific_Process_Knowledge/Characterization/ | | width="30" align="center" style="writing-mode: vertical-lr; transform: rotate(180deg);background:#f0f0f0;"|[[Specific_Process_Knowledge/Characterization/Topographic_measurement#Comparison of Stylus Profilers, Optical Profilers and AFMs at Nanolab|Optical profilers]] | ||
| width="30" align="center" style="writing-mode: vertical-lr; transform: rotate(180deg);background:#f0f0f0;"|[[Specific_Process_Knowledge/Characterization/Optical_characterization#Filmtek_4000|Filmtek (reflectometer)]] | | width="30" align="center" style="writing-mode: vertical-lr; transform: rotate(180deg);background:#f0f0f0;"|[[Specific_Process_Knowledge/Characterization/Optical_characterization#Filmtek_4000|Filmtek (reflectometer)]] | ||
| width="30" align="center" style="writing-mode: vertical-lr; transform: rotate(180deg);background:#f0f0f0;"|[[Specific_Process_Knowledge/Characterization/Optical_characterization#Ellipsometer|Ellipsometer]] | | width="30" align="center" style="writing-mode: vertical-lr; transform: rotate(180deg);background:#f0f0f0;"|[[Specific_Process_Knowledge/Characterization/Optical_characterization#Ellipsometer|Ellipsometer]] | ||
| Line 17: | Line 17: | ||
| width="30" align="center" style="writing-mode: vertical-lr; transform: rotate(180deg);background:#f0f0f0;"|[[Specific_Process_Knowledge/Characterization/XPS|XPS]] | | width="30" align="center" style="writing-mode: vertical-lr; transform: rotate(180deg);background:#f0f0f0;"|[[Specific_Process_Knowledge/Characterization/XPS|XPS]] | ||
| width="30" align="center" style="writing-mode: vertical-lr; transform: rotate(180deg);background:#f0f0f0;"|[[Specific_Process_Knowledge/Characterization/PL_mapper|PL mapper]] | | width="30" align="center" style="writing-mode: vertical-lr; transform: rotate(180deg);background:#f0f0f0;"|[[Specific_Process_Knowledge/Characterization/PL_mapper|PL mapper]] | ||
| width="30" align="center" style="writing-mode: vertical-lr; transform: rotate(180deg);background:#f0f0f0;"|[[ | | width="30" align="center" style="writing-mode: vertical-lr; transform: rotate(180deg);background:#f0f0f0;"|[[Specific Process Knowledge/Characterization/Four-Point Probe|4-point probe]] | ||
| width="30" align="center" style="writing-mode: vertical-lr; transform: rotate(180deg);background:#f0f0f0;"|[[Specific_Process_Knowledge/Characterization/Probe_station|Probe station]] | | width="30" align="center" style="writing-mode: vertical-lr; transform: rotate(180deg);background:#f0f0f0;"|[[Specific_Process_Knowledge/Characterization/Probe_station|Probe station]] | ||
| width="30" align="center" style="writing-mode: vertical-lr; transform: rotate(180deg);background:#f0f0f0;"|[[Specific_Process_Knowledge/Characterization/XRD|XRD]] | | width="30" align="center" style="writing-mode: vertical-lr; transform: rotate(180deg);background:#f0f0f0;"|[[Specific_Process_Knowledge/Characterization/XRD|XRD]] | ||
| Line 59: | Line 59: | ||
|- | |- | ||
|-style="background:#C0C0C0;" align="center" | |-style="background:#C0C0C0;" align="center" | ||
|align="left"| [[Specific_Process_Knowledge/Characterization/Element_analysis|Element analysis]]||||x||||||||||||||x||x 4 | |align="left"| [[Specific_Process_Knowledge/Characterization/Element_analysis|Element analysis]]||||x||||||||||||||x||x <sup>{{fn|4}}</sup>||||||x <sup>{{fn|4}}</sup>|||||||||||||| | ||
|- | |- | ||
|-style="background:#DCDCDC;" align="center" | |-style="background:#DCDCDC;" align="center" | ||
|align="left"| [[Specific_Process_Knowledge/Characterization/Stress_measurement|Film stress]]||||||||x||||||||||||||||||x 7 | |align="left"| [[Specific_Process_Knowledge/Characterization/Stress_measurement|Film stress]]||||||||x||||||||||||||||||x <sup>{{fn|7}}</sup>|||||||||||||| | ||
|- | |- | ||
|-style="background:#C0C0C0;" align="center" | |-style="background:#C0C0C0;" align="center" | ||
| Line 80: | Line 80: | ||
|- | |- | ||
|-style="background:#DCDCDC;" align="center" | |-style="background:#DCDCDC;" align="center" | ||
|align="left"| Reflectivity||||||||||||x||x||||||x 6 | |align="left"| Reflectivity||||||||||||x||x||||||x <sup>{{fn|6}}</sup>||||||||||||||||||||x | ||
|- | |- | ||
|-style="background:#C0C0C0;" align="center" | |-style="background:#C0C0C0;" align="center" | ||
| Line 89: | Line 89: | ||
|- | |- | ||
|-style="background:#C0C0C0;" align="center" | |-style="background:#C0C0C0;" align="center" | ||
|align="left"| Step coverage||x 1 | |align="left"| Step coverage||x <sup>{{fn|1}}</sup>||x <sup>{{fn|1}}</sup>|||||||||||||||||||||||||||||||||||| | ||
|- | |- | ||
|-style="background:#DCDCDC;" align="center" | |-style="background:#DCDCDC;" align="center" | ||
| Line 98: | Line 98: | ||
|- | |- | ||
|-style="background:#DCDCDC;" align="center" | |-style="background:#DCDCDC;" align="center" | ||
|align="left"| [[Specific_Process_Knowledge/Characterization/Measurement_of_film_thickness_and_optical_constants|Thin film thickness]]||x 1 | |align="left"| [[Specific_Process_Knowledge/Characterization/Measurement_of_film_thickness_and_optical_constants|Thin film thickness]]||x <sup>{{fn|1}}</sup>||x <sup>{{fn|1}}</sup>||x <sup>{{fn|2}}</sup>||x <sup>{{fn|2}}</sup>||x ||x||x||||||x <sup>{{fn|5}}</sup>||x <sup>{{fn|3}}</sup>||||x|||||||||||||| | ||
|- | |- | ||
|-style="background:#C0C0C0;" align="center" | |-style="background:#C0C0C0;" align="center" | ||
| Line 104: | Line 104: | ||
|- | |- | ||
|-style="background:#DCDCDC;" align="center" | |-style="background:#DCDCDC;" align="center" | ||
|align="left"| [[Specific_Process_Knowledge/Characterization/Thickness_Measurer|Wafer thickness]]||x 1 | |align="left"| [[Specific_Process_Knowledge/Characterization/Thickness_Measurer|Wafer thickness]]||x <sup>{{fn|1}}</sup>||x <sup>{{fn|1}}</sup>||||||||||||x|||||||||||||||||||||||| | ||
|- | |- | ||
|-style="background:#C0C0C0;" align="center" | |-style="background:#C0C0C0;" align="center" | ||
| Line 110: | Line 110: | ||
|- | |- | ||
|} | |} | ||
<br clear="all"> | |||
<sup>{{fn|1}}</sup> Using the cross section method<br> | |||
<sup>{{fn|2}}</sup> Using the create step method<br> | |||
<sup>{{fn|3}}</sup> With known resistivity<br> | |||
<sup>{{fn|4}}</sup> Composition information for crystalline materials<br> | |||
<sup>{{fn|5}}</sup> Only single layer<br> | |||
<sup>{{fn|6}}</sup> Good for characterization of VCSEL structures and DBR mirrors<br> | |||
<sup>{{fn|7}}</sup> Only for crystalline films<br> | |||
== Choose characterization topic == | == Choose characterization topic == | ||
| Line 144: | Line 141: | ||
===AFM=== | ===AFM=== | ||
*[[/AFM: Atomic Force Microscopy| | *[[/AFM: Atomic Force Microscopy|''Atomic Force Microscopy (AFM)'']] | ||
===Electrical measurements=== | ===Electrical measurements=== | ||
*[[/ | *[[/Four-Point Probe|4-Point Probe]] | ||
*[[/Probe station|Probe station]] | *[[/Probe station|Probe station]] | ||
*[[/III-V ECV-profiler|III-V ECV-profiler (Electrochemical Capacitance-Voltage carrier density profiler)]] | *[[/III-V ECV-profiler|III-V ECV-profiler (Electrochemical Capacitance-Voltage carrier density profiler)]] | ||
| Line 156: | Line 153: | ||
===Optical and stylus profilers=== | ===Optical and stylus profilers=== | ||
*[[/ | *[[/Sensofar_S_Neox|Sensofar S Neox (Optical Profiler)]] | ||
*[[/ | *[[/Dektak_XTA|Dektak XTA (Stylus Profiler)]] | ||
*[[/ | *[[/Tencor_P17|Tencor P17 (Stylus Profiler)]] | ||
*[[/ | *[[/Dektak_3ST|Dektak 3ST (Stylus profiler)]] | ||
*[[/ | *[[/Dektak_150|Dektak 150 (Stylus Profiler)]] | ||
===Optical microscopes=== | ===Optical microscopes=== | ||
| Line 173: | Line 170: | ||
===SEMs at DTU Nanolab - building 307/314=== | ===SEMs at DTU Nanolab - building 307/314=== | ||
<!-- *[[LabAdviser/CEN/Quanta 3D FIB/SEM|FIB-SEM FEI QUANTA 200 3D]] --> | <!-- *[[LabAdviser/CEN/Quanta 3D FIB/SEM|FIB-SEM FEI QUANTA 200 3D]] --> | ||
*[[LabAdviser/ | *[[LabAdviser/314/Microscopy 314-307/FIB/Helios|Dual Beam FEI Helios Nanolab 600]] | ||
*[[LabAdviser/ | *[[LabAdviser/314/Microscopy 314-307/SEM/Nova|SEM FEI Nova 600 NanoSEM]] | ||
*[[LabAdviser/ | *[[ | ||
LabAdviser/314/Microscopy 314-307/SEM/QFEG|SEM FEI Quanta 200 ESEM FEG]] | |||
<!-- *[[LabAdviser/CEN/Inspect S|SEM Inspect S]] --> | <!-- *[[LabAdviser/CEN/Inspect S|SEM Inspect S]] --> | ||
| Line 186: | Line 184: | ||
===TEMs at DTU Nanolab - building 307/314=== | ===TEMs at DTU Nanolab - building 307/314=== | ||
*[[LabAdviser/ | *[[LabAdviser/314/Microscopy 314-307/TEM/ATEM |Titan ATEM]] | ||
*[[LabAdviser/ | *[[LabAdviser/314/Microscopy 314-307/TEM/ETEM |Titan ETEM]] | ||
*[[LabAdviser/ | *[[LabAdviser/314/Microscopy 314-307/TEM/T20 |Tecnai TEM]] | ||
===XRD=== | ===XRD=== | ||
| Line 204: | Line 202: | ||
==Decommissioned equipment== | ==Decommissioned equipment== | ||
*[[/KLA-Tencor Surfscan 6420|KLA-Tencor Surfscan 6420]] | *[[/KLA-Tencor Surfscan 6420|KLA-Tencor Surfscan 6420]] | ||
*[[/X-Ray Diffractometer|Phillips X-Ray Diffractometer | *[[/X-Ray Diffractometer|Phillips X-Ray Diffractometer (owned by DTU Fotonik)]] | ||