==Thickness Measurer==
[[Image:Thicknessmeasurer2007.jpg|thumb|300x300px|Thickness Measurer. Positioned in cleanroom D-3]]


This is a micrometer-screw.
There are 2 thickness measurers in the cleanroom, both positioned in cleanroom D-3. The Thickness measurer is for measuring all sorts of samples. The thickness measurer (wafers) is solely for measuring the thickness of wafers or depths of grooves on wafers.  


[[image:Mikrometerskrue_hel_a.JPG|200x200px|right|thumb|The Thickness measurer in Cleanroom 3 ]]
During a KOH etch it can be helpful to ensure no over-etching by making a thickness measurement during the etching.  


It measures with an accurracy within a few µm.
 
The range is from a few µm up to 5mm.  
The user manual, technical information and contact information can be found in
Measure the wafer in the box next to the meter. If this is ok, then other wafers can be measured.
[http://www.labmanager.danchip.dtu.dk/function.php?module=Machine&view=view&mach=198 LabManager].
There is a calibration device by the DEKTAK.
 
It is calibrated at 750µm.
==Quality Control - Recipe Parameters and Limits==
{| border="1" cellspacing="2" cellpadding="2" colspan="3"
|bgcolor="#98FB98" |'''Quality Control (QC) for the Thickness measurer'''
|-
|
The measured standard thickness is 0.1 mm. The measured result has to be within &plusmn; 0.005 mm. The QC is preformed once a year.
*[http://www.labmanager.danchip.dtu.dk/d4Show.php?id=1831&mach=198 The QC procedure]<br>
*[https://labmanager.dtu.dk/view_binary.php?type=data&mach=198 The newest QC data]<br>
|}
<br> <br>
 
==Equipment performance and process related parameters==
 
{| border="2" cellspacing="2" cellpadding="3"
 
|-
!style="background:silver; color:black;" align="center"|
Purpose
|style="background:LightGrey; color:black"|
Thickness measurer
|style="background:WhiteSmoke; color:black"|
*Wafer thickness
*Depths of larger grooves
*Heigth of larger samples
|-
!style="background:silver; color:black" align="center"|
Performance
|style="background:LightGrey; color:black"|
Thickness resolution
|style="background:WhiteSmoke; color:black"|
*< 1 µm
|-
!style="background:silver; color:black" align="center" valign="center" rowspan="2"|
Substrates
|style="background:LightGrey; color:black"|
Batch size
|style="background:WhiteSmoke; color:black"|
*One sample
|-
| style="background:LightGrey; color:black"|Substrate materials allowed
|style="background:WhiteSmoke; color:black"|
*No restrictions
|-
|}
<br>
{| border="2" cellspacing="2" cellpadding="3"
 
|-
!style="background:silver; color:black;" align="center"|
Purpose
|style="background:LightGrey; color:black"|
Thickness measurer (wafers)
|style="background:WhiteSmoke; color:black"|
*Wafer thickness
*Depths of larger grooves
|-
!style="background:silver; color:black" align="center"|
Performance
|style="background:LightGrey; color:black"|
Thickness resolution
|style="background:WhiteSmoke; color:black"|
*< 1 µm
|-
!style="background:silver; color:black" align="center" valign="center" rowspan="2"|
Substrates
|style="background:LightGrey; color:black"|
Batch size
|style="background:WhiteSmoke; color:black"|
*One sample
|-
| style="background:LightGrey; color:black"|Substrate materials allowed
|style="background:WhiteSmoke; color:black"|
*Only wafers
|-
|}