==Probe station==
{{cc-nanolab}}
 
'''Feedback to this page''': '''[mailto:labadviser@nanolab.dtu.dk?Subject=Feed%20back%20from%20page%20http://labadviser.nanolab.dtu.dk/index.php/Specific_Process_Knowledge/Characterization/Probe_station click here]'''
<br>
<br>
=Probe Station=
[[Image:probe2.jpg|thumb|300x300px|Probe station. Positioned in serviceroom CX1]]
[[Image:probe2.jpg|thumb|300x300px|Probe station. Positioned in serviceroom CX1]]


'''Feedback to this page''': '''[mailto:labadviser@danchip.dtu.dk?Subject=Feed%20back%20from%20page%20http://labadviser.danchip.dtu.dk/index.php/Specific_Process_Knowledge/Characterization/Probe_Station click here]'''
The Probe station is a - EPS150Triax - Cascade. The purpose is to measure I/V measurement, ohmic measurements etc. It has 4 individually adjustable triax connected probes, but can be fitted with additional coax connected probes. The stage can be moved in x and y to step and repeat a measurement over a large number of chips.


The Probe station is a - EPS150Triax - Cascade. The purpose is to measure I/V measurement, ohmic measurements etc, it has 4 individually adjustable triax connected probes, but can be fitted with additional coax connected.  
Samples can be inspected by either a microscope and/or a camera.


It has several source meters, multi meters and a computer attached.
Two Keithley 2450 source meters are connected to the probe station by triax cables. An additional Keithley 2410 source meter and a Keithley 2000 multi meter is connected by coax cables. All Keithleys can also be connected with banana wires.


==Equipment performance and process related parameters==
 
The user manual, technical information and contact information can be found in
[http://www.labmanager.danchip.dtu.dk/function.php?module=Machine&view=view&mach=343 '''Labmanager]'''.
 
 
==Performance and Process Parameters==


{| border="2" cellspacing="2" cellpadding="3"  
{| border="2" cellspacing="2" cellpadding="3"  
Line 20: Line 30:
*I/V
*I/V
*Resistance
*Resistance
*Heigth of larger mesas
*Data collection by PC possible
|-
|-
!style="background:silver; color:black" align="center"|
!style="background:silver; color:black" align="center"|
Line 41: Line 51:
|-  
|-  
|}
|}
'''The user manual, technical information and contact information can be found in LabManager:'''
'''[http://www.labmanager.danchip.dtu.dk/function.php?module=Machine&view=view&mach=343 Probe station]'''