'''Feedback to this page''': '''[mailto:photolith@danchip.dtu.dk?Subject=Feed%20back%20from%20page%20http://labadviser.danchip.dtu.dk/index.php/Specific_Process_Knowledge/Bonding/Eutectic_bonding click here]''' | '''Feedback to this page''': '''[mailto:photolith@danchip.dtu.dk?Subject=Feed%20back%20from%20page%20http://labadviser.danchip.dtu.dk/index.php/Specific_Process_Knowledge/Bonding/Eutectic_bonding click here]''' | ||
<br> | |||
<br> | |||
==Eutectic Bonding== | ==Eutectic Bonding== | ||
Eutectic bonding depends on a formation of an eutecticum in the bond interphase. This makes bonding of two substates by use of eg. a AuSi eutecticum possible at temperatures much lower than the actual melting points of either of the two (in this case bonding can be done at around 390<sup>o</sup>C). The bonding strecth is quite good, but far from as good as anodic bonding. Different eutectica have a different eutectic (bonding) temperature | Eutectic bonding depends on a formation of an eutecticum in the bond interphase. This makes bonding of two substates by use of eg. a AuSi eutecticum possible at temperatures much lower than the actual melting points of either of the two (in this case bonding can be done at around 390<sup>o</sup>C). The bonding strecth is quite good, but far from as good as anodic bonding. Different eutectica have a different eutectic (bonding) temperature | ||