Specific Process Knowledge/Wafer and sample drying/Spin Dryers: Difference between revisions
Appearance
Created page with "=== Spin dryers === 200x200px|right|thumb|Image(s) of the equipment(s) A tool used for drying wafers. A single cassette of wafers is p..." |
|||
| (13 intermediate revisions by 4 users not shown) | |||
| Line 1: | Line 1: | ||
=== Spin dryers | '''Feedback to this page''': '''[mailto:pvd@danchip.dtu.dk?Subject=Feed%20back%20from%20page%20http://labadviser.danchip.dtu.dk/index.php?title=Specific_Process_Knowledge/Wafer_and_sample_drying/Spin_Dryers click here]''' | ||
= Spin dryers = | |||
[[image:spin-rinser-dryer-white.jpg|200x200px|right|thumb|Image(s) of the equipment(s)]] | [[image:spin-rinser-dryer-white.jpg|200x200px|right|thumb|Image(s) of the equipment(s)]] | ||
| Line 11: | Line 15: | ||
'''The user manual | '''The user manual, technical information, and contact information can be found in LabManager: [http://labmanager.danchip.dtu.dk/function.php?module=Machine&view=view&mach=157 Spin dryer 2] [http://labmanager.danchip.dtu.dk/function.php?module=Machine&view=view&mach=158 Spin dryer 3] [https://labmanager.dtu.dk/function.php?module=Machine&view=view&mach=408 Spin dryer 5][https://labmanager.dtu.dk/function.php?module=Machine&view=view&mach=323 Spindryer 6 (8")]''' | ||
== Process information == | |||
Standard process is 120 seconds for 100mm wafers or 180 seconds for 150mm wafers, at 2000 RPM - drying only. | |||
''If'' rinsing is used as well, the standard process is 60 seconds of rinse at 500 RPM, followed by 120/180 seconds of drying at 2000 RPM. | |||
<br clear="all" /> | |||
{| border="2" cellspacing="0" cellpadding="2" | |||
!colspan="2" border="none" style="background:silver; color:black;" align="center"|Equipment | |||
|style="background:WhiteSmoke; color:black"|<b>Spin dryer 2</b> | |||
|style="background:WhiteSmoke; color:black"|<b>Spin dryer 3</b> | |||
|style="background:WhiteSmoke; color:black"|<b>Spin dryer 5</b> | |||
|style="background:WhiteSmoke; color:black"|<b>Spin dryer 6</b> | |||
|- | |||
!style="background:silver; color:black;" align="center" width="60"|Location | |||
|style="background:LightGrey; color:black"| | |||
|style="background:WhiteSmoke; color:black"| | |||
*B-1 | |||
|style="background:WhiteSmoke; color:black"| | |||
*D-3 | |||
|style="background:WhiteSmoke; color:black"| | |||
*D-3 | |||
|style="background:WhiteSmoke; color:black"| | |||
*F-3 | |||
|- | |||
!style="background:silver; color:black;" align="center" width="60"|Purpose | |||
|style="background:LightGrey; color:black"| | |||
|style="background:WhiteSmoke; color:black"| | |||
*Drying | |||
|style="background:WhiteSmoke; color:black"| | |||
*Drying | |||
*Rinsing + drying | |||
|style="background:WhiteSmoke; color:black"| | |||
*Drying | |||
|style="background:WhiteSmoke; color:black"| | |||
*Drying | |||
*Rinsing + drying | |||
|- | |||
!style="background:silver; color:black" align="center" valign="center" rowspan="3"|Substrates | |||
|style="background:LightGrey; color:black"|Batch size | |||
|style="background:WhiteSmoke; color:black"| | |||
*1-25 100 mm wafers | |||
|style="background:WhiteSmoke; color:black"| | |||
*1-25 100 mm wafers | |||
*1-25 150 mm wafers | |||
|style="background:WhiteSmoke; color:black"| | |||
*1-25 100 mm wafers | |||
*1-25 150 mm wafers | |||
|style="background:WhiteSmoke; color:black"| | |||
*1-25 100 mm wafers | |||
*1-25 150 mm wafers | |||
*1-25 200 mm wafers | |||
|- | |||
| style="background:LightGrey; color:black"|Allowed materials | |||
|style="background:WhiteSmoke; color:black"| | |||
*Only for RCA cleaned wafers | |||
|style="background:WhiteSmoke; color:black"| | |||
*No restrictions | |||
|style="background:WhiteSmoke; color:black"| | |||
*No restrictions | |||
|style="background:WhiteSmoke; color:black"| | |||
*No restrictions | |||
|- | |||
|} | |||