{| {{table}} | |||
| align="center" style="background:#f0f0f0;"|'''Nominal trench line width''' | |||
| align="center" style="background:#f0f0f0;"|'''''' | |||
| align="center" style="background:#f0f0f0;"|'''30''' | |||
| align="center" style="background:#f0f0f0;"|'''60''' | |||
| align="center" style="background:#f0f0f0;"|'''90''' | |||
| align="center" style="background:#f0f0f0;"|'''120''' | |||
| align="center" style="background:#f0f0f0;"|'''150''' | |||
| align="center" style="background:#f0f0f0;"|'''Avg''' | |||
| align="center" style="background:#f0f0f0;"|'''Std''' | |||
|- | |||
| ER||nm/min||183||218||232||249||256||228||29 | |||
|- | |||
| SA||degs||95||94||94||93||93||94||1 | |||
|- | |||
| base||nm/edge||-2||-4||-16||-15||-27||-13||10 | |||
|- | |||
| foot||nm/edge||-2||-4||-16||-15||3||-7||9 | |||
|- | |||
| Bowing||||36||40||49||48||40||42||6 | |||
|- | |||
| Curve||||-55||-50||-39||-39||-42||-45||7 | |||
|- | |||
| zep||nm/min||||||||||||172|| | |||
|- | |||
| | |||
|} | |||
== Comments == | == Comments == | ||
The lower coil power run may still be isotropic-looking either because of a lack of deposition in the process, or because the bias increases as the coil power is decreased, hence the wafer would have received a more phyisically-aggressive process. Lower temp, lower coil + lower platen may be worth a look. | The lower coil power run may still be isotropic-looking either because of a lack of deposition in the process, or because the bias increases as the coil power is decreased, hence the wafer would have received a more phyisically-aggressive process. Lower temp, lower coil + lower platen may be worth a look. |
Revision as of 12:51, 10 May 2011
The nano1.1 recipe
Recipe | Gas | C4F8 38 sccm, SF6 52 sccm |
---|---|---|
Pressure | 4 mTorr, Strike 3 secs @ 15 mTorr | |
Power | 600 W CP, 50 W PP | |
Temperature | 10 degs | |
Hardware | 100 mm Spacers | |
Time | 120 secs | |
Conditions | Run ID | 1815 |
Conditioning | Sequence: Oxygen clean, MU tests, processes, no oxygen between runs | |
Mask | 1dfhj10 nm zep etched down to 6dgh4 nm |
-
The 30 nm trenches
-
The 60 nm trenches
-
The 90 nm trenches
-
The 120 nm trenches
-
The 150 nm trenches
Nominal trench line width | ' | 30 | 60 | 90 | 120 | 150 | Avg | Std |
ER | nm/min | 183 | 218 | 232 | 249 | 256 | 228 | 29 |
SA | degs | 95 | 94 | 94 | 93 | 93 | 94 | 1 |
base | nm/edge | -2 | -4 | -16 | -15 | -27 | -13 | 10 |
foot | nm/edge | -2 | -4 | -16 | -15 | 3 | -7 | 9 |
Bowing | 36 | 40 | 49 | 48 | 40 | 42 | 6 | |
Curve | -55 | -50 | -39 | -39 | -42 | -45 | 7 | |
zep | nm/min | 172 | ||||||
Comments
The lower coil power run may still be isotropic-looking either because of a lack of deposition in the process, or because the bias increases as the coil power is decreased, hence the wafer would have received a more phyisically-aggressive process. Lower temp, lower coil + lower platen may be worth a look.