Specific Process Knowledge/Wafer cleaning: Difference between revisions

From LabAdviser
Jump to navigation Jump to search
No edit summary
No edit summary
 
(7 intermediate revisions by 4 users not shown)
Line 1: Line 1:
'''Feedback to this page''': '''[mailto:labadviser@nanolab.dtu.dk?Subject=Feed%20back%20from%20page%20http://labadviser.danchip.dtu.dk/index.php/Specific_Process_Knowledge/Wafer_cleaning click here]'''  
'''Feedback to this page''': '''[mailto:labadviser@nanolab.dtu.dk?Subject=Feed%20back%20from%20page%20http://labadviser.danchip.dtu.dk/index.php/Specific_Process_Knowledge/Wafer_cleaning click here]'''  
'''Unless anything else is stated, everything on this page, text and pictures are made by DTU Nanolab.'''
'''All links to Labmanager requires login.'''
'''All measurements on this page has been made by Nanolab staff.'''


== Cleaning of wafers ==
== Cleaning of wafers ==
__NOTOC__
__NOTOC__
During processing it is sometimes mandatory, necessary or just recommended to clean the wafers or the photo lithographic masks. This can be done by different cleaning procedures depending on what the wafers have been exposed to and where they are going to be further processed. In the comparison table below is listed different cleaning procedures available at Danchip.
During processing it is sometimes mandatory, necessary or just recommended to clean the wafers or the photo lithographic masks. This can be done by different cleaning procedures depending on what the wafers have been exposed to, and where they are going to be further processed. In the comparison table below is listed different cleaning procedures available at nanolab.




Line 17: Line 23:


===Items that have been outside the cleanroom===
===Items that have been outside the cleanroom===
Before bringing samples into the cleanroom you have to get approval from Danchip. Send an e-mail to '''[mailto:danchipsupport@danchip.dtu.dk?Subject=Request%20for%20bringing%20samples%20into%20the%20cleanroom&body=Describe%20your%20samples:%0AWhy%20you%20need%20to%20bring%20them%20in%20the%20cleanroom:%0Aand%20which%20processes%20your%20are%20going%20to%20use:  danchipsupport@danchip.dtu.dk]'''.  
Before bringing samples into the cleanroom you have to get approval from Nanolab. Send an e-mail to '''[mailto:nanolabsupport@nanolab.dtu.dk?Subject=Request%20to%20bring%20samples%20into%20the%20cleanroom&body=Describe%20your%20samples:%0AWhy%20you%20need%20to%20bring%20them%20in%20the%20cleanroom:%0Aand%20which%20processes%20your%20are%20going%20to%20use:  nanolabsupport@nanolab.dtu.dk]'''.  


When you have an approval the items that have been outside the cleanroom should always be cleaned in soap and ultra sound followed by a 7-up or Piranha clean before entering the cleanroom.  
When you have an approval the items that have been outside the cleanroom should always be cleaned in soap and ultra sound followed by a 7-up or Piranha clean before entering the cleanroom.  
Line 58: Line 64:
Make the surface hydrophillic  
Make the surface hydrophillic  
|Removing dust and particles
|Removing dust and particles
|
|Removing slurry residues from the CMP
|-
|-


Line 69: Line 75:
|Recommended cleaning and treatment before wafer bonding  
|Recommended cleaning and treatment before wafer bonding  
|Mandatory cleaning of very dirty items that enters the cleanroom. Should always be followed by a piranha clean.
|Mandatory cleaning of very dirty items that enters the cleanroom. Should always be followed by a piranha clean.
|
|Recommended cleaning after CMP
|-
|-


Line 85: Line 91:
*<nowiki>#</nowiki>1-25 2" and 4" wafers
*<nowiki>#</nowiki>1-25 2" and 4" wafers
|
|
*All sizes that can go into the bath|
*All sizes that can go into the bath
|
*<nowiki>#</nowiki>1 20x20mm sample as well as 2", 4" and 6inch wafers 
|-
|-


Line 126: Line 134:
*All materials
*All materials
|
|
*Silicon
*Poly Silicon
*Silicon Oxide
*Quartz/fused silica
|-
|-


|}
|}

Latest revision as of 09:40, 2 February 2023

Feedback to this page: click here

Unless anything else is stated, everything on this page, text and pictures are made by DTU Nanolab.

All links to Labmanager requires login.

All measurements on this page has been made by Nanolab staff.

Cleaning of wafers

During processing it is sometimes mandatory, necessary or just recommended to clean the wafers or the photo lithographic masks. This can be done by different cleaning procedures depending on what the wafers have been exposed to, and where they are going to be further processed. In the comparison table below is listed different cleaning procedures available at nanolab.


Wafers that go into the high temperature furnaces

As a general rule all wafers that go into the high temperature furnaces need a full RCA clean directly before the furnace step.

Wafers that have been in KOH baths (Si Etch 1, 2 and 3), KOH BHF baths or 'Nitride etch: H3PO4' (warm phosphoric acid)

Wafers that have been etched in KOH are often etched in warm phosphoric acid afterwards to strip the silicon nitride etch mask. Therefore, wafers that have been processed in KOH baths, KOH BHF baths or phosphoric acid nitride etch baths often need at minimum a 7-up or Piranha clean before they can be further processed (in order to remove KOH etch residuals and metal ions).

Items that have been outside the cleanroom

Before bringing samples into the cleanroom you have to get approval from Nanolab. Send an e-mail to nanolabsupport@nanolab.dtu.dk.

When you have an approval the items that have been outside the cleanroom should always be cleaned in soap and ultra sound followed by a 7-up or Piranha clean before entering the cleanroom.

Masks

Masks that have become dirty by dust particles or resist residues have to be cleaned in the 7-up (mask) bath before use.

Before entering specific process equipment

Sometimes the wafers need a certain cleaning process before they can enter specific process equipments due to the risk of cross contamination. Please consult the cross contamination scheme to see whether your wafers need a cleaning before the next processing sequence.


Comparison of Wafer Cleaning Methods

RCA Wafer/Mask Clean baths & Piranha 5% HF IMEC Soap Sonic Post CMP Cleaner
Generel description Two step process to remove traces of organics and metals Removes traces of organics and alkali ions Removing native oxide Removing dust, traces of organics and alkali ions and slightly polish the surface.

Make the surface hydrophillic

Removing dust and particles Removing slurry residues from the CMP
Purpose Mandatory prior furnace processes When needed and always after KOH etch and Nitride etch in Phosphoric acid. Sometimes mandatory before next processing step. Optional during RCA cleaning Recommended cleaning and treatment before wafer bonding Mandatory cleaning of very dirty items that enters the cleanroom. Should always be followed by a piranha clean. Recommended cleaning after CMP
Substrate size
  • #1-25 2", 4" and 6" wafers
  • #1-25 2", 4" and 6" wafers
  • #1-25 2", 4" and 6" wafers
  • #1-25 2" and 4" wafers
  • All sizes that can go into the bath
  • #1 20x20mm sample as well as 2", 4" and 6inch wafers
Allowed materials
  • Silicon
  • Poly Silicon
  • Silicon Oxide
  • Silicon Nitride
  • Silicon Oxynitride
  • Quartz/fused silica
  • Silicon
  • Poly Silicon
  • Silicon Oxide
  • Silicon Nitride
  • Silicon Oxynitride
  • Quartz/fused silica
  • Pyrex, other glass and Silicon wafers with Cr ONLY allowed in Mask Cleaning bath or beaker in fumehood
  • Silicon
  • Poly Silicon
  • Silicon Oxide
  • Silicon Nitride
  • Silicon Oxy-nitride
  • Quartz/fused silica
  • Resists (depending on bath)
  • Pyrex (depending on bath)
  • Silicon
  • Poly Silicon
  • Silicon Oxide
  • Silicon Nitride
  • Silicon Oxynitride
  • Quartz/fused silica
  • Pyrex
  • All materials
  • Silicon
  • Poly Silicon
  • Silicon Oxide
  • Quartz/fused silica