'''Unless anything else is stated, everything on this page, text and pictures are made by DTU Nanolab.'''
'''All links to Kemibrug (SDS) and Labmanager Including APV and QC requires login.'''
'''Feedback to this page''': '''[mailto:labadviser@danchip.dtu.dk?Subject=Feed%20back%20from%20page%20http://labadviser.danchip.dtu.dk/index.php/Specific_Process_Knowledge/Etch/Etching_of_Titanium click here]'''
<!--Page reviewed by jmli 1/8-2016  -->
==Etching of Titanium==
==Etching of Titanium==
[[Image:Fumehoodetch-chrom2.jpg|300x300px|thumb|Fume hood: positioned in cleanroom 2. <br />Wet Etch of Chromium can take place in a beaker in this fume hood]]


Etching of Titanium is done wet at Danchip. We have two solutions for titanium etching:
Etching of titanium can be done either by wet etch, dry etch or by sputtering with ions.
 
*[[Specific Process Knowledge/Etch/Wet Titanium Etch|Etching of Ti by wet etch]]
# BHF
*[[Specific Process Knowledge/Etch/ICP Metal Etcher/Titanium|Etching of Ti by dry etch]]
# Cold RCA1
*[[Specific_Process_Knowledge/Etch/IBE&frasl;IBSD Ionfab 300/IBE Ti etch|Sputtering of Ti]]
<br clear="all" />


Do it by making your own set up in a beaker in a fume hood - preferably in cleanroom 2 or 4. BHF etching can also take place in the PP-etch bath in the fume hood in cleanroom 2.
==Comparison of Titanium Etch Methodes==


{|border="1" cellspacing="1" cellpadding="3" style="text-align:left;"
|-


===Comparing the two solutions===
|-
|-style="background:silver; color:black"
!
![[Specific Process Knowledge/Etch/Wet Titanium Etch|Ti wet etch 1]]
![[Specific Process Knowledge/Etch/Wet Titanium Etch|Ti wet etch 2]]
![[Specific_Process_Knowledge/Etch/ICP_Metal_Etcher|ICP metal]]
![[Specific_Process_Knowledge/Etch/IBE&frasl;IBSD Ionfab 300|IBE (Ionfab300+)]]
|-


{| border="1" cellspacing="0" cellpadding="4" align="left"
|-
!  
|-style="background:WhiteSmoke; color:black"
! BHF
!Generel description
! Cold RCA1  
|BHF Etch of titanium with or without photoresist mask.
|-  
|Cold RCA1 mix etch of titanium (as stripper or with eagle resist).
|'''General description'''
|Dry plasma etch of Ti
|Sputtering of Ti - pure physical etch
|-
 
|-
|-style="background:LightGrey; color:black"
!Etch rate range
|
|
Etch of titanium with or without photoresist mask.
*~?nm/min
|
|
Etch of titanium (as stripper or with eagle resist).
*~?nm/min
|-
|
|'''Chemical solution'''
*~50-200 nm/min (depending on features size and etch load and recipe settings)
|HF:NH<math>_4</math>F 
|  
|NH<math>_3</math>OH:H<math>_2</math>O<math>_2</math>:H<math>_2</math>O - 1:1:5
*~20nm/min
|-
|-
|'''Process temperature'''
|Room temperature
|Room temperature


|-
|-
 
|-style="background:WhiteSmoke; color:black"
|'''Possible masking materials'''
!Etch profile
|
*Isotropic
|
*Isotropic
|
|
Photoresist (1.5 µm AZ5214E)
*Anisotropic (vertical sidewalls)
|
|
Eagle resist
*Anisotropic (angles sidewalls, typical around 70 dg)
|-
|-
|'''Etch rate'''
 
 
|-
|-style="background:LightGrey; color:black"
!Substrate size
|
|
Not known (it bubbles while etching)
*Any size and number that can go inside the beaker in use
|
|
Not known
*Any size and number that can go inside the beaker in use
|-
|'''Batch size'''
|
|
1-5 4" in beaker
*smaller pieces on a carrier wafer
1-25 wafers at a time in PP-etch bath
*<nowiki>#</nowiki>1 100mm wafers (if you place it/bond it on a 150 mm carrier wafer)
*<nowiki>#</nowiki>1 150mm wafers  
|
|
1-5 4" wafer at a time
Smaller pieces glued to carrier wafer
*<nowiki>#</nowiki>1 50mm wafer
*<nowiki>#</nowiki>1 100mm wafer
*<nowiki>#</nowiki>1 150mm wafer
*<nowiki>#</nowiki>1 200mm wafer
|-
|-
|'''Etch bath'''
 
|Beaker or PP-etch bath in the fume hood in cleanroom 2.
|Beaker
|-
|-
|'''Allowed materials'''
|-style="background:WhiteSmoke; color:black"
!'''Allowed materials'''
|
|
No restrictions when used in beaker or PP-etch bath in the fume hood in cleanroom 2.
No restrictions cross contamination wise as long as you use the right beaker and make sure that they are safe to enter in the chemicals
Make a note on the beaker of which materials have been processed.
|
|
No restrictions when used in beaker.
No restrictions cross contamination wise as long as you use the right beaker and make sure that they are safe to enter in the chemicals
Make a note on the beaker of which materials have been processed.
|
*Silicon
*Quartz/fused silica
*Photoresist/e-beam resist
*PolySilicon,
*Silicon oxide
*Silicon (oxy)nitride
*Aluminium
*Titanium
*Chromium
|
*Silicon
*Silicon oxides
*Silicon nitrides
*Metals from the +list
*Metals from the -list
*Alloys from the above list
*Stainless steel
*Glass
*III-V materials
*Resists
*Polymers
*Capton tape
|-
|-
|}
|}

Latest revision as of 14:36, 18 April 2024

Unless anything else is stated, everything on this page, text and pictures are made by DTU Nanolab.

All links to Kemibrug (SDS) and Labmanager Including APV and QC requires login.

Feedback to this page: click here

Etching of Titanium

Etching of titanium can be done either by wet etch, dry etch or by sputtering with ions.


Comparison of Titanium Etch Methodes

Ti wet etch 1 Ti wet etch 2 ICP metal IBE (Ionfab300+)
Generel description BHF Etch of titanium with or without photoresist mask. Cold RCA1 mix etch of titanium (as stripper or with eagle resist). Dry plasma etch of Ti Sputtering of Ti - pure physical etch
Etch rate range
  • ~?nm/min
  • ~?nm/min
  • ~50-200 nm/min (depending on features size and etch load and recipe settings)
  • ~20nm/min
Etch profile
  • Isotropic
  • Isotropic
  • Anisotropic (vertical sidewalls)
  • Anisotropic (angles sidewalls, typical around 70 dg)
Substrate size
  • Any size and number that can go inside the beaker in use
  • Any size and number that can go inside the beaker in use
  • smaller pieces on a carrier wafer
  • #1 100mm wafers (if you place it/bond it on a 150 mm carrier wafer)
  • #1 150mm wafers

Smaller pieces glued to carrier wafer

  • #1 50mm wafer
  • #1 100mm wafer
  • #1 150mm wafer
  • #1 200mm wafer
Allowed materials

No restrictions cross contamination wise as long as you use the right beaker and make sure that they are safe to enter in the chemicals

No restrictions cross contamination wise as long as you use the right beaker and make sure that they are safe to enter in the chemicals

  • Silicon
  • Quartz/fused silica
  • Photoresist/e-beam resist
  • PolySilicon,
  • Silicon oxide
  • Silicon (oxy)nitride
  • Aluminium
  • Titanium
  • Chromium
  • Silicon
  • Silicon oxides
  • Silicon nitrides
  • Metals from the +list
  • Metals from the -list
  • Alloys from the above list
  • Stainless steel
  • Glass
  • III-V materials
  • Resists
  • Polymers
  • Capton tape