| =<span style="background:#FF2800">THIS PAGE IS UNDER CONSTRUCTION</span>[[image:Under_construction.png|200px]]=
| | The SEM Jeol has been decommissioned at Danchip and is currently waiting for new owners to take over. |
| | |
| '''Feedback to this page''': '''[mailto:labadviser@danchip.dtu.dk?Subject=Feed%20back%20from%20page%20http://labadviser.danchip.dtu.dk/index.php/Specific_Process_Knowledge/Characterization/SEM_Jeol#SEM_JEOl click here]'''
| |
| | |
| =SEM JEOL=
| |
| | |
| [[image:IMG_3290.jpg|400x400px|right|thumb|Picosun R200 ALD, positioned in cleanroom F-2.]]
| |
| | |
| The SEM Jeol is located in the basement of DTU Danchip. I will very soon be decommissioned (within 2015) and replaced and by the SEM Supra 1 (former SEM Zeiss). | |
| | |
| | |
| '''The user manual, control instruction, the user APV and contact information can be found in LabManager:'''
| |
| | |
| [http://labmanager.dtu.dk/function.php?module=Machine&view=view&mach=149 SEM Jeol info page in LabManager],
| |
| | |
| | |
| == Performance information ==
| |
| | |
| *[[/SEM comparison tablel|SEM comparison table]]
| |
| | |
| | |
| | |
| ==Equipment performance and process related parameters==
| |
| | |
| {| border="2" cellspacing="0" cellpadding="2"
| |
| | |
| !colspan="2" border="none" style="background:silver; color:black;" align="center"|Equipment
| |
| |style="background:WhiteSmoke; color:black"|<b>SEM Jeol (Jeol JSM 5500 LV)</b>
| |
| |-
| |
| !style="background:silver; color:black;" align="center" width="60"|Purpose
| |
| |style="background:LightGrey; color:black"|Imaging and measurement of
| |
| |style="background:WhiteSmoke; color:black"|
| |
| *Any samples including samples from outside the cleanroom and samples that have a thin (> ~ 5 µm) layers of non-conducting materials on top
| |
| |-
| |
| !style="background:silver; color:black;" align="center" width="60"|Location
| |
| |style="background:LightGrey; color:black"|
| |
| |style="background:WhiteSmoke; color:black"|
| |
| *Basement of DTU Danchip
| |
| |-
| |
| !style="background:silver; color:black;" align="center" width="60"|Performance
| |
| |style="background:LightGrey; color:black"|Resolution
| |
| |style="background:WhiteSmoke; color:black"|
| |
| *~ 20 nm (limited by instrument)
| |
| The resolution is strongly dependent on the type of sample and the skills of the operator.
| |
| |-
| |
| !style="background:silver; color:black" align="center" valign="center" rowspan="4"|Instrument specifics
| |
| |style="background:LightGrey; color:black"|Detectors
| |
| |style="background:WhiteSmoke; color:black"|
| |
| *Secondary electron (SEI)
| |
| *Backscatter electron (BEI)
| |
| |-
| |
| |style="background:LightGrey; color:black"|Stage
| |
| |style="background:WhiteSmoke; color:black"|
| |
| *X, Y: 73 × 40 mm
| |
| *T: -10 to 90<sup>o</sup>
| |
| *R: 360<sup>o</sup>
| |
| *Z: 38 mm
| |
| |-
| |
| |style="background:LightGrey; color:black"|Electron source
| |
| |style="background:WhiteSmoke; color:black"|
| |
| *Tungsten filament
| |
| |-
| |
| |style="background:LightGrey; color:black"|Operating pressures
| |
| |style="background:WhiteSmoke; color:black"|
| |
| *Fixed at High vacuum
| |
| | |
| |-
| |
| !style="background:silver; color:black" align="center" valign="center" rowspan="3"|Substrates
| |
| |style="background:LightGrey; color:black"|Batch size
| |
| |style="background:WhiteSmoke; color:black"|
| |
| *1 100 mm wafer (not full view)
| |
| *Smaller samples
| |
| |-
| |
| | style="background:LightGrey; color:black"|Allowed materials
| |
| |style="background:WhiteSmoke; color:black"|
| |
| *Any standard cleanroom materials.
| |
| *Biological samples
| |
| |-
| |
| |}
| |
The SEM Jeol has been decommissioned at Danchip and is currently waiting for new owners to take over.