Specific Process Knowledge/Etch/Etching of Gold: Difference between revisions

From LabAdviser
Line 3: Line 3:


# Iodine etch: KI:I<math>_2</math>:H<math>_2</math>O - 100g:25g:500ml - standard at Danchip. Can be used with resist as mask.
# Iodine etch: KI:I<math>_2</math>:H<math>_2</math>O - 100g:25g:500ml - standard at Danchip. Can be used with resist as mask.
# Aqua Regia (Kongevand): HNO<math>_3</math>:HCl - 1:3 - It is a very strong acid witch will etch most metals and are therefore used when you wish to remove all the gold from your wafer. '''Be very carefull when you work with Aqua Regia (Kongevand) It can generate nitrous gases witch are very toxic!!'''
# Aqua Regia (Kongevand): HNO<math>_3</math>:HCl - 1:3 - It is a very strong acid witch will etch most metals and are therefore used when you wish to remove all the gold from your wafer. '''you have to be very carefull when you work with Aqua Regia (Kongevand) It can generate nitrous gases witch are very toxic!!'''





Revision as of 14:47, 4 February 2008

Etching of Gold

Etching of Gold is done wet at Danchip making your own set up in a beaker in the fumehood. We have two different solutions:

  1. Iodine etch: KI:I:HO - 100g:25g:500ml - standard at Danchip. Can be used with resist as mask.
  2. Aqua Regia (Kongevand): HNO:HCl - 1:3 - It is a very strong acid witch will etch most metals and are therefore used when you wish to remove all the gold from your wafer. you have to be very carefull when you work with Aqua Regia (Kongevand) It can generate nitrous gases witch are very toxic!!


Comparing the two solutions

Iodine based gold etch Aqua Regia (Kongevand)
General description

Etch of pure Gold

Etch of pure Gold

Chemical solution KJ:J:HO (100g:25g:500ml) HCl:HNO (3:1)
Process temperature 20 oC 20 oC
Possible masking materials

Photoresist (1.5 µm AZ5214E)

Unmasked - used as a stripper

Etch rate

~100 nm/min

~(??) nm/min - fast etch

Batch size

1-25 wafers at a time

1-25 wafer at a time

Size of substrate

2-6" wafers

2-6" wafers