For constant mould temperature processes it is a good idea to manually close the mould cooling water valves '''e''' and '''g'''. For reproducible results it is also a good idea to make sure that you always run at the same temperature setpoint for the mould casing cooling water controllers (see Chapter 4.11 in the [http://labmanager.dtu.dk/d4Show.php?id=2081&mach=278 manual]).
For constant mould temperature processes it is a good idea to manually close the mould cooling water valves '''e''' and '''g'''. For reproducible results it is also a good idea to make sure that you always run at the same temperature setpoint for the mould casing cooling water controllers (see Chapter 4.11 in the [http://labmanager.dtu.dk/d4Show.php?id=2081&mach=278 manual]). A setpoint around 70°C for both sides works well in most cases.


=== 2. Variable mould temperature (Variotherm) processes ===
=== 2. Variable mould temperature (Variotherm) processes ===

Revision as of 13:33, 24 August 2016

Mold temperature setup

Injection moulding processes can be divided into two different types:

  1. Constant mould temperature processes
  2. Variable mould temperature (Variotherm) processes


1. Constant mould temperature processes

In this type of process the mould remains at the same temperature during the entire injection moulding cycle. The temperature should not exceed the glass transition temperature of the polymer being used. Otherwise the polymer will never get cold enough to solidify to a degree where it can be demoulded without being deformed/damaged. How close one can get to the glass transition temperature depends on several factors like e.g. polymer type, cooling time and whether the polymer has a tendency to stick to the shim (especially an issue when replicating high aspect ratio structures). With Topas 5013L-10 (which has a Tg around 135°C) one can often go up to 100°C and for samples that are easy to demold even higher (110-120°C). For polymers with very low Tg (such as e.g. flexible polyurethanes) one often has to run as cold as possible. With the mould heeting switched completely off and mould cooling water fully open, the lowest achievable mould temperature is around 15°C.


Parameter Benefits Drawbacks
Low mould temperature Very fast cycle times due to short cooling times Problems with replication of small features because polymer solidifies prior to complete filling
High mould temperature Reasonably short cycle times, improved replication Problems with demoulding


For constant mould temperature processes it is a good idea to manually close the mould cooling water valves e and g. For reproducible results it is also a good idea to make sure that you always run at the same temperature setpoint for the mould casing cooling water controllers (see Chapter 4.11 in the manual). A setpoint around 70°C for both sides works well in most cases.