Template:Mask spec: Difference between revisions

From LabAdviser
Kabi (talk | contribs)
No edit summary
Kabi (talk | contribs)
No edit summary
 
(4 intermediate revisions by 2 users not shown)
Line 1: Line 1:
   
   
  <nowiki>
  <nowiki>
Lyngby 20.06.15


For 5" masks:
Lyngby 12.07.19
All Layers:
All Layers:
5" chromium mask
5" chromium mask
Soda-lime Glass
fracture limits ((-50000, -50000),(50000, 50000))
Dark periphery
Chromium down
 
GDS-file: GLO006_v7.gds
Top cell: wafer
 
Layer (GDS number): 01
Mask Type: Digitised data= Dark, right reading
Text(max 30 characters): init-2019-Nitride-etch
 
Layer (GDS number): 02
Mask Type: Digitised data= Clear, Wrong reading
Text(max 30 characters): init-2019-KOH-backside
 
 
Yours sincerely
Nancy Noname
 
 
 
For 7" masks:
 
 
Lyngby 12.07.19
All Layers:
7" chromium mask
fracture limits ((-70000, -70000),(70000, 70000))
Dark periphery
Dark periphery
Chromium down
Chromium down


CIF-file: MyMask.cif (or MyMask.gds)
GDS-file: GLO006_v7.gds
Top cell: Wafer (usually)
Top cell: wafer
 
 
Layer: MT1
Layer (GDS number): 01
Mask Type: Clear field, Right reading
Mask Type: Digitised data= Dark, right reading
Text: DTU PicoTech - Nancy Noname - jun 2015 - Front side mask
Text(max 30 characters): init-2019-Nitride-etch


Layer: MT2
Layer (GDS number): 02
Mask Type: Dark field, Wrong reading
Mask Type: Digitised data= Clear, Wrong reading
Text: DTU PicoTech - Nancy Noname - jun 2015 - Back side mask
Text(max 30 characters): init-2019-KOH-backside




Yours sincerely  
Yours sincerely  
Nancy Noname
</nowiki>
</nowiki>

Latest revision as of 14:21, 29 August 2019


For 5" masks:


Lyngby 12.07.19
All Layers:
	5" chromium mask
	fracture limits ((-50000, -50000),(50000, 50000))
	Dark periphery
	Chromium down

GDS-file: GLO006_v7.gds
Top cell: wafer

Layer (GDS number): 01 
Mask Type: Digitised data= Dark, right reading
Text(max 30 characters): init-2019-Nitride-etch

Layer (GDS number): 02
Mask Type: Digitised data= Clear, Wrong reading
Text(max 30 characters): init-2019-KOH-backside


Yours sincerely 
Nancy Noname



For 7" masks:


Lyngby 12.07.19
All Layers:
	7" chromium mask
	fracture limits ((-70000, -70000),(70000, 70000))
	Dark periphery
	Chromium down

GDS-file: GLO006_v7.gds
Top cell: wafer

Layer (GDS number): 01 
Mask Type: Digitised data= Dark, right reading
Text(max 30 characters): init-2019-Nitride-etch

Layer (GDS number): 02
Mask Type: Digitised data= Clear, Wrong reading
Text(max 30 characters): init-2019-KOH-backside


Yours sincerely 
Nancy Noname